Radwin 5000 HPMP User Manual page 283

5000 series point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

HSU
Table 12‐2: HBS Performance Monitoring Fields (Continued)
Abbreviation 
Column Heading
Meaning
Background 
BBE
Block Error
Received 
Rx MBytes
Mbytes
Transmitted 
Tx MBytes
Mbytes
Above Traffic 
Threshold set in 
Thresh
Figure 12‐7
Active Seconds
Data becomes invalidated following a reset. In the example below, the HBS was reset shortly 
after 11:00. All data prior to that time becomes invalidated. The only valid item is the first 
recording after re‐sync.
Figure 12‐9: HBS ‐ Performance Monitoring report ‐ Showing invalid data
Use the Save button to store the current data to file and the Clear button to delete currently 
stored performance data.
HSU
The Performance Monitoring window for the HSU is slightly different depending on whether 
you access it from the HBS or directly:
From the HBS
RADWIN 5000 HPMP User Manual
Description
The number of errored blocks in an interval.
The number of Megabytes received at the specified 
port within the interval
The number of Megabytes transmitted at the 
specified port within the interval.
Seconds count when actual traffic exceeded the 
threshold
The number of seconds that the configured Ethernet 
service is active
Release  3.5.70
12‐12