Siemens SIMOVERT MASTERDRIVES Manual page 355

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Communication / PROFIBUS
Example for the
actual-value channel
At the converter via PMU
P734.1 = 32
P694.1 = 968
P734.2 = 151
P694.2 = 218
P734.4 = 33
P694.4 = 553
Example: 32-bit main actual value
P734.2 = 151
P694.2 = 218
P734.3 = 151
P694.3 = 218
NOTE
8.2-68
PZD interconnection for status word 1 (ZSW1), the main actual value
(HIW) and status word 2 (ZSW2).
Status word 1 (K032 /
channel by means of PZD1.
The actual speed n/f (KK151 / P218) is transferred in the actual-value
channel by means of PZD2 (here, as a 16-bit quantity; PZD3 is
empty).
Status word 2 (K033 / P553) is transferred in the actual-value
channel by means of PZD4.
The actual speed n/f (KK151 / P218) is transferred in the actual-value
channel by means of PZD2 ...
... and as a 32-bit value by means of PZD3.
• Italics:
P734 / P694 (
CB/TB actual value), if PMU is shown as a decimal number,
transferred via PROFIBUS-DP as an equivalent HEX (2B6 Hex).
:
Single underline
Index (if PMU is a decimal number, via PROFIBUS-DP as an equivalent HEX
number): Specifies at which position in the PZD actual-value telegram the
actual value selected by the parameter number is transferred
• Double underline:
Parameter number of the required actual value
• White background =
• Grey background =
If actual values are transferred as a 32-bit data item, you must enter the
appropriate connector number at two consecutive words (indices).
Meaning
P968
) is transferred in the actual-value
MASTERDRIVES Compact PLUS,
CUPM, CUMC or CUVC (first
CBP)
MASTERDRIVES FC (CU1),
VC (CU 2) or SC (CU 3)
6SE7087-6QX70 (Version AG)
Compendium Motion Control
.
.
Siemens AG
SIMOVERT MASTERDRIVES
05.2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents