Siemens SIMOVERT MASTERDRIVES Manual page 117

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Parameterization
5.5.3
Parameterization
5.5.3.1
Structure of the parameter lists, parameterization with DriveMonitor
Field
Field Name
No.
1
P. Nr
2
Name
3
Ind
4
Index text
5
Parameter
value
6
Dim
5-38
Parameterization using the parameter list is basically the same as
parameterization using PMU (See Chapter 6 "Parameterizating Steps").
The parameter list provides the following advantages:
♦ Simultaneous visibility of a larger number of parameters
♦ Text display for parameter names, index number, index text,
parameter value, binectors, and connectors
♦ On a change of parameters: Display of parameter limits or possible
parameter values
The parameter list has the following structure:
Function
Here the parameter number is displayed. You can only change the field in
menu Free parameterization.
Display of the parameter name, in accordance with the parameter list
Display of the parameter index for indexed parameters. To see more than
index 1, click on the [+] sign. The display is then expanded and all indices of
the parameter are displayed
Meaning of the index of the parameter
Display of the current parameter value. You can change this by double-
clicking on it or selecting and pressing Enter.
Physical dimension of the parameter, if there is one
6SE7087-6QX70 (Version AF)
Compendium Motion Control
01.2006
Siemens AG
SIMOVERT MASTERDRIVES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents