01.2006
5.4.3.6
OP: Download
Siemens AG
6SE7087-6QX70 (Version AF)
SIMOVERT MASTERDRIVES
With the "OP: Download" function, a parameter set stored in the OP1S
can be written into the connected slave. Starting from the basic menu,
the "OP: Download" function is selected with "Lower" or "Raise" and
activated with "P".
P
MotionControl
Download
*Menu selection
*1909199701
OP: Upread
MASTERDRIVES MC
#OP: Download
Example: Selecting and activating the "Download" function
One of the parameter sets stored in the OP1S must now be selected
with "Lower" or "Raise" (displayed in the second line). The selected ID
is confirmed with "P". The slave ID can now be displayed with "Lower"
or "Raise" (see section "Slave ID"). The "Download" procedure is then
started with "P". During download, the OP1S displays the currently
written parameter.
P
Download
Download
*1909199701
*1909199701
MASTERDRIVES MC
MASTERDRIVES MC
Example: Confirming the ID and starting the "Download" procedure
With "Reset", the procedure can be stopped at any time. If downloading
has been fully completed, the message "Download ok" appears and the
display returns to the basic menu.
After the data set to be downloaded has been selected, if the
identification of the stored software version does not agree with the
software version of the unit, an error message appears for
approximately 2 seconds. The operator is then asked whether
downloading is to be discontinued.
P
Download
Download
*1909199701
*1909199701
MASTERDRIVES MC
MASTERDRIVES MC
Yes:
The "Download" procedure is discontinued.
No:
The "Download" procedure is carried out.
Compendium Motion Control
P
MotionControl 00
Download
Pxxx
P
2 s
Error:
MotionControl 00
Different
Stop download?
IDs
#yes
no
Parameterization
5-21