Siemens SIMOVERT MASTERDRIVES Manual page 110

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

01.2006
5.4.4.2
Changing slaves
5.4.5
Technical data
Siemens AG
6SE7087-6QX70 (Version AF)
SIMOVERT MASTERDRIVES
During bus operation, a specific slave can be selected via the OP1S
with the "Change slave" function without any re-plugging. Starting from
the basic menu, the "Change slave" function is selected with the
"Lower"/"Raise" key and activated with "P". The user is then requested
to enter a slave address.
P
Change slave
MotionControl
Download
Address:00
Delete data
#Change slave
Example of activating the "Change slave" function
After the slave address has been entered with "Raise"/"Lower" and
confirmed with "P", a change is made to the required slave and the
display returns to the basic menu. If the slave cannot be found, an error
message is output.
Order number
Supply voltage
Operating temperature
Storage temperature
Transport temperature
Environment class
Humidity
Pollution resistance
Protection class
Degree of protection
Front
Rear
Dimensions W x H x D
Standards
Table 5-11
Technical data
Compendium Motion Control
Parameterization
6SE7090-0XX84-2FK0
5 V DC ± 5 %, 200 mA
0 °C to +55 °C
-25 °C to +70 °C
-25 °C to +70 °C
Acc. to DIN IEC 721 Part 3-3/04.90
03K3
13C3
II acc. DIN VDE 0160 Part 1/05.82
IEC 536/1976
Acc. to DIN VDE 0470 Part 1/11.92
IP54
EN60529
IP21
74 x 174 x 26 mm
VDE 0160/E04.91
VDE 0558 Part 1/07.87
UL, CSA
5-31