02.2007
P060 = 5
P071 = ?
P095 = ?
P095 = 1
2 3
4
P096=?
P097=?
P101 = ?
P102 = ?
P102 = ?
P103 = ?
P104 = ?
P107 = ?
P108 = ?
P108 = ?
Siemens AG
6SE7087-6QX70 (Version AH)
SIMOVERT MASTERDRIVES
Select "Drive setting" menu
Input unit line voltage in V
AC units: RMS value of AC voltage
DC units: DC link voltage
Input of motor type
0: No motor connected
1: Synchronous servomotor 1FT6/1FK6
5
2: Asynchronous servomotor 1PH7(=1PA6)/1PL6/1PH4
3: Synchronous servomotor general
4: Asynchronous servomotor
5: Torque motor 1FW3
Input of code number for the connected
1FK6/1FT6 motor (see list attached)
Input of code number for the connected
1PH7(=1PA6)/1PL6/1PH4 motor (see list attached)
Input of code number for the connected 1FW3 motor
P099 = ?
(see list attached)
Input of motor rated voltage in V
according to rating plate
Input of motor rated current in A
according to rating plate
Input of magnetizing current in A
If this is not known, enter "0" here. The value is then calculated
by the automatic parameterization.
Input of power factor cos(phi)
according to rating plate
Input of motor rated frequency in Hz
according to rating plate
Input of motor rated speed in rpm
according to rating plate