Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Functions
Evaluation
3
3
1.5
0
-1.5
Oper_dB
-3
-4.5
-6
-6
1
fmin
180
180
135
90
45
0
Phase
-45
-90
-135
-180
-180
1
fmin
7-60
The recorded data are automatically stored in file
"C:\Siemens\DriveMonitor\P7vrvisx\Projects\Drives\MASTERDRIVES
MC\ TRACE.TXT" when read out with DriveMonitor. Existing files are
overwritten. The file is an ASCII file with integer values and commas as
separators, which can be imported into commercial mathematical
programs.
Evaluation of the data in a mathematical program is the task of the
user, i.e. the user must first create a worksheet in a mathematical
program in which he or she edits, evaluates, and graphically represents
the data as required.
One suitable program is, for example, the mathematical software"
"Mathcad ® " produced by the company MathSoft
(http://www.mathsoft.com), which provides a relatively uncomplicated
introduction to the subject area.
The following graphics show the amplitude and phase response of the
closed speed control loop (factory setting, without optimization). The
data was evaluated and displayed graphically using "Mathcad 8 ® ".
10
Frequency in Hz (no omega!)
10
Frequency in Hz (no omega!)
Fig. 7-15
100
Frequency
100
Frequency
6SE7087-6QX70 (Version AG)
Compendium Motion Control
05.2006
3
.
1
10
fmax
1
.
10
fmax
Siemens AG
SIMOVERT MASTERDRIVES
3

Hide quick links:

Advertisement

Table of Contents