05.2006
8.2.4.7
Example of "Change parameter value", multi-parameter
Siemens AG
6SE7087-6QX70 (Version AG)
SIMOVERT MASTERDRIVES
Parameter task:
Task header
Task reference
Axis = 0
st
1
parameter address Attribute = value
Parameter number
Subindex = 7
nd
2
parameter
Attribute = value
address
Parameter number
Subindex = 0
rd
3
parameter address Attribute = value
Parameter number
Subindex = 0
st
1
parameter value(s) Format = word
Value
nd
2
parameter
Format = word
value(s)
Value 1
Value 2
...
Value 100
rd
3
parameter value(s) Format = double
word
Value1
Value2
Parameter response (+): All part access o.k.
Response header
Compendium Motion Control
Task identifier =
Change parameter
No. of parameters = 3
No. of elements = 1
No. of elements = 100
No. of elements = 2
No. of values = 1
No. of values = 100
No. of values = 2
Task ref. mirrored
Response identifier =
Change parameter (+)
Axis mirrored
No. of parameters = 3
Communication / PROFIBUS
Offset
0
2
4
10
16
22
24
26
28
228
230
238
0
2
4