B0892 : F_REF_WD
fault Reference
point correction
outside window 2
Siemens AG
6SE7087-6QX70 (Version AG)
SIMOVERT MASTERDRIVES
Binector for masking window homing
(see "Masking window for homing" section)
Status binectors/connectors/visualization parameters
The parameter U862 BPos RM-Signal shows the status of the basic
positioner as status signals.
Index 1 :
BPos (K0888) input
BIT0
= ENABLE_POS
BIT1
= RESERVED
BIT2
= POS
BIT3
= SETUP
BIT4
= POS_TYP_ACT (was: ABS_REL)
BIT5
= D_FWD_ACT
BIT6
= D_BWD_ACT
BIT7
= EXT_REF_OK B0888 or B0210 = 1
BIT8
= EXT_POS_OK
BIT9
= SET_TRIG
BIT10 = Internal POS_OK (reached position)
Index 2 :
BPos output and homing command (K0889)
BIT16 = B0860 [POS_OK]
BIT17 = B0861 [POS_RUN]
BIT18 = B0862 [RFG_RUN]
BIT19 = B0863 [RU_ACT]
BIT20 = B0864 [RD_ACT]
BIT21 = B0866 [FWD_RUN]
BIT22 = B0867 [BWD_RUN]
BIT23 = B0865 [POS_DELTA]
BIT24 = B0868 [SW_E_PLUS]
BIT25 = B0869 [SW_E_MINUS]
BIT26 = B0888 [ARFD]
BIT27 = B0892 [F_REF_WD]
Compendium Motion Control
Functions
7-43