l
/l
r
ine
oad
eaCTors
Supply: 230V, 3Ø, 50/60 Hz (Variable Torque; reactor installed Line or Load Side)
VT: 3Ø
Output
GS4 Model
hp
Amps
(rms)
GS4-21P0
1
5
GS4-22P0
2
8
GS4-23P0
3
11
GS4-25P0
5
17
GS4-27P5
7�5
25
GS4-2010
10
33
GS4-2015
15
49
GS4-2020
20
65
GS4-2025
25
75
GS4-2030
30
90
GS4-2040
40
120
GS4-2050
50
146
GS4-2060
60
180
GS4-2075
75
215
GS4-2100
100
255
* Some GS4 drive and reactor combinations do not fit the typical "pattern" of having similar part numbers,
due to some GS4 models having higher outputs than previous GS DURApulse drives.
Supply: 460V, 3Ø, 50/60 Hz (Variable Torque; reactor installed Line or Load Side)
VT: 3Ø
Output
GS4 Model
hp
Amps
(rms)
GS4-41P0
1
3
GS4-42P0
2
4
GS4-43P0
3
6
GS4-45P0
5
9
GS4-47P5
7�5
12
GS4-4010
10
18
GS4-4015
15
24
GS4-4020
20
32
GS4-4025
25
38
GS4-4030
30
45
GS4-4040
40
60
GS4-4050
50
73
GS4-4060
60
91
GS4-4075
75
110
GS4-4100
100
150
GS4-4125
125
180
GS4-4150
150
220
GS4-4175
175
260
GS4-4200
215
310
GS4-4250
250
370
GS4-4300
300
460
DuRA
GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
pulse
s
C
(
eleCTion
harTs
ConTinued
Inductance (mH)
Saturation
Amps
3%
(rms)
Impedance
8�7
2�536
12�8
1�585
18
1�152
29
0�746
43
0�507
56
0�320
85
0�216
112
0�163
128
0�169
155
0�141
205
0�106
250
0�087
308
0�070
367
0�059
436
0�049
Inductance (mH)
Saturation
Amps
3%
(rms)
Impedance
5�2
8�102
6�8
6�077
10�3
4�050
14�6
2�700
20
2�025
31
1�174
41
0�881
54
0�660
65
0�639
77
0�541
103
0�405
124
0�334
155
0�267
189
0�221
257
0�162
308
0�135
376
0�110
445
0�098
531
0�078
634
0�066
787
0�054
)
Max Motor
LR Model*
5%
kW
Impedance
4�226
0�75
LR-21P0
2�641
1�5
LR-23P0*
1�921
2�2
LR-23P0
1�244
3�7
LR-25P0
0�845
5�5
LR-27P5
0�534
7�5
LR-2010
0�359
11
LR-2015
0�271
15
LR-2020
0�282
18�5
LR-2025
0�236
22
LR-2040*
0�176
30
LR-2040
0�146
37
LR-2050
0�117
45
0�098
55
available*
0�082
75
Max
Motor
LR Model
5%
kW
Impedance
13�503
0�75
10�128
1�5
6�751
2�2
4�500
3�7
3�375
5�5
1�957
7�5
1�468
11
1�101
15
1�066
18�5
0�901
22
0�675
30
0�556
37
0�445
45
0�368
55
0�270
75
0�224
90
0�184
110
0�163
132
0�130
160
0�109
185
0�090
220
Appendix A: Accessories
Rated
LR 3%
Amps
Inductance
4�6
2�46
10�6
0 �97
10�6
0�97
16�7
0�626
24�2
0�434
30�8
0�342
46�2
0�22
59�4
0�172
74�8
0�138
114
0�0886
114
0�0886
143
0�0699
169
0�0624
not
211
0�0487
273
0�0364
Rated
LR 3%
Amps
Inductance
LR-41P0
2�1
8�927
LR-42P0
3�4
5�790
LR-43P0
4�8
4�270
LR-45P0
7�6
2�770
LR-47P5
11
1�680
LR-4010
14
1�290
LR-4015
21
0�912
LR-4020
27
0�694
LR-4025
34
0�569
LR-4030
40
0�469
LR-4040
52
0�387
LR-4050
65
0�295
LR-4060
77
0�227
LR-4075
96
0�196
LR-4100
124
0�152
LR-4125
156
0�117
LR-4150
180
0�103
LR-4200
240
0�0839
LR-4250
302
0�0654
LR-4250
302
0�0654
LR-4300
361