dura
gs4 aC D
pulse
s
T
Torage and
ransporTaTion
AC drives should be kept in the shipping cartons or crates until they are installed. In order to
retain the warranty coverage, they should be stored as described below if not to be installed and
used within three months.
• Store in a clean and dry location free from direct sunlight and corrosive fumes.
• Store within environmental conditions shown below in the "Environmental Conditions" table.
• DO NOT store in an area with rapid changes in temperature , to avoid condensation and frost.
• DO NOT place directly on the ground.
If the drive is stored or is otherwise unused for more than a year, the drive's internal DC link
capacitors should be recharged before use. Otherwise, the capacitors may be damaged when the
drive starts to operate. We recommend recharging the capacitors of any unused drive at least
once per year. (Refer to Chapter 6, "Maintenance and Troubleshooting" for information about
recharging DC link capacitors.)
e
C
nvironmenTal
ondiTions
Condition
Installation Location
IEC60364-1/IEC60664-1 Pollution degree 2, Indoor use only
Ambient Temperature
Relative Humidity
Air Pressure
Pollution Level
Altitude
(see separate derating section for altitudes of 1000–3000m)
Package Drop
1.0mm, peak to peak value range from 2Hz to 13.2 Hz; 0.7G~1.0G range from 13.2Hz to 55Hz; 1.0G range
Vibration
Impact
Installation
Orientation
Frame Size
230V: 1.0~30 hp
A~C
460V: 1.0~40 hp
230V: >30hp
460V: >40hp
D0~G
230V: >30hp
460V: >40hp
* Only the exposed terminal blocks are IP00; the other components are IP20
DuRA
GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
pulse
e
rive
nvirOnMental
Environmental Conditions for GS4 AC Drives
Operation
see separate Operating Temperature table below
Max 90%, non-condensing, non-frozen
86 to 106 kPa
Class 3C2; Class 3S2
0~1000m
n/a
from 55Hz to 512 Hz. Comply with IEC 60068-2-6
Max allowed offset angle ±10° (from vertical installation position)
Operating Temperature and Protection Level
Top cover
Conduit Box Protection Level
With top cover removed Standard
conduit plate
With top cover in place
With conduit
N/A
box
Without
N/A
conduit box
Chapter 1: Getting Started
i
nfOrMatiOn
Storage
n/a
Max 95%, non-condensing, non-frozen
IEC721-3-3, no concentrate
Class 2C2; Class 2S2
n/a
ISTA procedure 1A(according to weight)
IEC/EN 60068-2-27
IP20 / UL Open Type
IP20 / UL Type1 / NEMA1
IP20 / UL Type1 / NEMA1
IP00 / IP20 / UL Open Type *
Only the circled area is IP00.
Other parts are IP20.
Transportation
n/a
-25°C to +70°C
70 to 106 kPa
Class 1C2; Class 1S2
n/a
IEC60068-2-31
10°
10°
Operating
Temperature
-10~50°C [14~122°F]
-10~40°C [14~104°F]
-10~40°C [14~104°F]
-10~50°C [14~122°F]
Page 1–9