Chapter 4: AC Drive Parameters
P9.47
Comm Card Fault Code
Range/Units (Format: 16-bit unsigned)
0~65535
This parameter displays applicable Fault Codes for the currently installed communications card.
NOTE: Fault Parameters are explained in Parameter Group P11.xx
error messages are show in Chapter 6: Maintenance and Troubleshooting
P9.48
Comm Card IP Configuration
Range/Units (Format: 16-bit binary)
0: Static IP – User needs to set the IP address manually�
1: Dynamic IP (DHCP) – IP address will be automatically set by the
host controller�
This parameter displays the configuration of the currently installed communications card.
We strongly recommend using the Static IP setting. If using Dynamic IP, the DHCP server
may unexpectedly change the GS4 IP address. This could cause any external PLCs, HMIs,
etc., to lose communication to the drive.
P9.49
Comm Card IP Address Octet 1
P9.50
Comm Card IP Address Octet 2
P9.51
Comm Card IP Address Octet 3
P9.52
Comm Card IP Address Octet 4
P9.53
Comm Card Mask Octet 1
P9.54
Comm Card Mask Octet 2
P9.55
Comm Card Mask Octet 3
P9.56
Comm Card Mask Octet 4
P9.57
Comm Card Gateway Octet 1
P9.58
Comm Card Gateway Octet 2
P9.59
Comm Card Gateway Octet 3
P9.60
Comm Card Gateway Octet 4
Range/Units (Format: 16-bit unsigned)
0~255
The octet addresses 1 through 4 are from left to right.
For more detailed Ethernet information, refer to Appendix B: Optional I/O and Communication Cards.
When P9.xx parameters are changed, the new communication card parameter values must
be "pushed" from the P9 parameters to the card. See P9.64.
P9.61
reserved
P9.62
reserved
P9.63
Comm Card Factory Reset
Range/Units (Format: 16-bit binary)
0: No Action
1: Reset to the Factory Setting
When the card is reset to Factory Defaults, the P9 parameters still retain their values (IP addresses,
Masks, etc.) in the GS4 AC drive. To re-write the drive parameters back into the card, use P9.64.
Page 4–188
DURA
GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
pulse
Type
Hex Addr Dec Addr
Read
092F
Default
0
(page
4–206), and the Fault Code
(page
6–16).
Type
Hex Addr Dec Addr
R/W
0930
Default
0
Type
Hex Addr Dec Addr
♦ R/W
0931
♦ R/W
0932
♦ R/W
0933
♦ R/W
0934
♦ R/W
0935
♦ R/W
0936
♦ R/W
0937
♦ R/W
0938
♦ R/W
0939
♦ R/W
093A
♦ R/W
093B
♦ R/W
093C
Default
0
Type
Hex Addr Dec Addr
~
093D
~
093E
Type
Hex Addr Dec Addr
R/W
093F
Default
0
42352
42353
42354
42355
42356
42357
42358
42359
42360
42361
42362
42363
42364
42365
42366
42367
42368