P8.08
Power On Counter
Range/Units (Format: 16-bit unsigned)
0~65535
Records the number of power cycles.
P8.09
Power On Day
Range/Units (Format: 16-bit unsigned)
0~65535
Records the number of days the drive has been powered on.
P8.10
Power On Minute
Range/Units (Format: 16-bit unsigned)
0~1439
Records the number of minutes the drive has been powered on.
After this parameter reaches 1,439 minutes it will roll over to 0, and P8.09 will increment by 1 day.
P8.11
Accumulative Motor Operation Time (minute)
Range/Units (Format: 16-bit unsigned)
0~1439
P8.12
Accumulative Motor Operation Time (day)
Range/Units (Format: 16-bit unsigned)
0~65535
P8.11 and P8.12 record motor operation time. Both parameters can be cleared by setting to 00.
Operation time less than 60 seconds will not be recorded.
P8.13
Keypad Communication Fault Treatment
Range/Units (Format: 16-bit binary)
0: Warn & Continue Operation
1: Warn & Ramp to Stop
2: Warn & Coast to Stop
3: No Warning & Continue Operation
This parameter sets the response to a keypad communication fault.
N OTE: Use this parameter with P8.14 to enable Keypad Loss Detection. This is especially useful when
the drive is being controlled from the keypad or from External Terminals (with Keypad Stop Enabled).
NOTE: P8.14 must be > 0 for this Parameter to enable Keypad Timeout (disconnected keypad).
P8.14
Keypad Time Out
Range/Units (Format: 16-bit unsigned)
0�0~100�0 sec
This parameter sets the keypad time out. After the time-out period ends with no communications,
the keypad will display "Keypad time out" "CP10," and the drive will respond according to the
setting of P8.13 (Keypad Communication Fault Treatment).
NOTE: If P8.13 = 3 (No Warning), the drive will not respond to a loss of keypad communication.
DURA
GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
pulse
Chapter 4: AC Drive Parameters
Type
Hex Addr
Read
0808
Default
~
Type
Hex Addr
Read
0809
Default
~
Type
Hex Addr
Read
080A
Default
~
Type
Hex Addr
Read
080B
Default
~
Type
Hex Addr
Read
080C
Default
~
Type
Hex Addr
R/W
080D
Default
2
Type
Hex Addr
R/W
080E
Default
1�0
Dec Addr
42057
Dec Addr
42058
Dec Addr
42059
Dec Addr
42060
Dec Addr
42061
Dec Addr
42062
Dec Addr
42063