The inverter can only process the SYNC mechanism in multiples of milliseconds. For
this reason the allowed values for object 0x1006/0
multiples of milliseconds.
E.g.: 0x1006/0 = 4000 = 4 ms
communication cycle period
If the
the time distance between the SYNC messages over the first 11 messages. Please
note, that the monitoring function is deactivated for setting "0". The measurement is
solely for internal uses of the frequency inverter. The time must not change after
the measurement.
The time distance between two consecutive SYNC messages is monitored.
If object 0x1006/0
then a communication error event is triggered whenever the time defined by
0x1006/0 is exceeded by more than 50%.
After SYNC telegram "A", SYNC telegram "B" has to be received latest after the set
SYNC time + 50 %.
If object 0x1006/0
toring function is not active.
Example:
Read Request
Reply
Write Access
Reply
CB: Control byte
58
is NOT set (0x1006/0 = 0), the inverter measures
communication cycle period
communication cycle period
COB ID CB
Index
601
40
06 10
581
43
06 10
601
23
06 10
581
60
06 10
SI: Sub Index All values in hexadecimal without leading 0x
CM-CAN ACU
communication cycle period
is set to a value other than zero,
is not set (= zero), then this moni-
SI
Data
00
00 00 00 00
00
00 00 00 00
00
A0 0F 00 00
00
00 00 00 00
are
04/13