0X6098/0 Homing Method - BONFIGLIOLI Vectron Active Cube User Manual

Canopen communication module cm-can frequency inverter 230 v / 400 v
Table of Contents

Advertisement

12.5.37 0x6098/0 Homing method

Index Sub-index
0x6098
0
Object works in:
Motion Control x40:
Homing mode
o
Object 0x6098/0
homing. For a detailled description of the different homing modes see the application
manual "Positioning".
Writing to object
ter
Homing Mode
If object 0x6098/0 was written and then a save parameters command (object 0x1010)
processed, the object value is stored in non volatile memory.
After the next power on of the inverter, the previously set value is reactivated and
overwrites the setting of parameter
Homing Method
0 - No Homing
1 - Neg. Limit Switch & Ref. -Signal
2 - Pos. Limit Switch & Ref. -Signal
Pos. Home-Sw., Ref.-Signal left
3 -
of Edge
Pos. Home-Sw., Ref.-Signal right
4 -
of Edge
Neg. Home-Sw., Ref.-Signal
5 -
right of Edge
Neg. Home-Sw.: Ref.-Signal left
6 -
of Edge
Pos. Lim.-Sw., Ref.-Sig. left of
7 -
left Edge of Home-Sw.
146
Meaning
Homing method
Object doesn't work in:
homing method
homing method
automatically generates a write command to parame-
1130 (data set 5, all data sets in RAM only !).
0x6098/0
Factory setting. No homing; the current position
value is not changed. The current position value is
the value saved upon the last disconnection of the
power supply.
Homing to negative HW limit switch with detection
of encoder ref. signal.
Homing to positive HW limit switch with detection of
encoder ref. signal.
Homing to positive home switch with detection of
encoder ref. signal. Home position is the first encod-
er ref. signal to the left of the edge of the home
switch signal.
Homing to positive home switch with detection of
encoder ref. signal. Home position is the first encod-
er ref. signal to the right of the edge of the home
switch signal.
Homing to negative home switch with detection of
encoder ref. signal. Home position is the first encod-
er ref. signal to the right of the edge of the home
switch signal.
Homing to negative home switch with detection of
encoder ref. signal. Home position is the first encod-
er ref. signal to the left of the edge of the home
switch signal.
Homing to home switch with detection of encoder
ref. signal. Homing direction positive (clockwise).
CM-CAN ACU
Data type
Integer8
Motion Control x40:
Profile Positioning mode
o
Profile Velocity mode
o
Velocity mode
o
Interpolated mode
o
Table Travel record mode
o
Move away from Limit Switch
o
Electronic Gear: Slave
o
Non motion Control (conf. ≠ x40)
determines the method that will be used during
1130.
Homing Mode
Function
Access
Map
Def.-Val
rw
No
0
04/13