12.5.3
0x6040/0 Control word
Index Sub-index
0x6040
0
Object 0x6040/0
ever parameter
15 14 13 12 11 10 9
Bits 4, 5, 6 and 9 ... 15 are used in motion control configurations (p.30 = x40) only.
See chapter 14 "Inverter Control" and 16.1 "Control Word overview".
Example:
Read Request
Reply
Write Access
Reply
CB: Control byte
04/13
Meaning
Control word
Control word
is relevant to the inverter remote state machine when-
412 is set to 1 (remote state machine).
LocalRemote
8
7
COB ID CB
601
40
581
4B
601
2B
581
60
SI: Sub Index All values in hexadecimal without leading 0x
CM-CAN ACU
Data type
Unsigned16
Control word
6
5
4
3
2
1
0 Bit
Index
SI
Data
40 60
00
00 00
40 60
00
01 00
40 60
00
06 00
40 60
00
00 00
Access
Map Def.-Val
rw
Rx
0
0
Switch on
1
Enable voltage
2
Quick stop (Low active)
3
Enable operation
4
Operation mode specific
5
Operation mode specific
6
Operation mode specific
7
Fault reset
8
Halt
9
Operation mode specific
10
Reserved
11
Manufacturer specific
12
Manufacturer specific
13
Manufacturer specific
14
Manufacturer specific
15
Manufacturer specific
115