11.11 Fault Reset

Depending on the settings and the operating status of the device a fault reset can be
done like described:
− When using control via parameter
Set bit 7 in 0x6040 Control word = 0x0080.
− Via the Stop key of the operator panel
A reset via the STOP key can only be executed, if Parameter
lows the control via keypad
− via parameter
digital input
A reset via a digital input can only be executed, if Parameter
lows that control or if a physical input with the suffix (Hardware) is selected.
Some faults might re-occur after a fault reset. In these cases a certain action might
be necessary (in example move away from a limit switch in the non-locked direction).
44
Local/Remote
Error Acknowledgement
CM-CAN ACU
412 = Statemachine:
Local/Remote
103 which is assigned a logic signal or a
Local/Remote
412 al-
412 al-
04/13