If objects 0x6046/1 or 0x6046/2 were written and then a save parameters command
(object 0x1010) processed, the object values are stored in non volatile memory. After
the next power on of the inverter, the previously set values are reactivated and over-
write the settings of parameters
419.
cy
In Positioning applications the overall speed can fall below or exceed the limits defined
by Minimum and Maximum frequency due to the influence of the Position controller.
The output of the Position Controller can be limited by
Example:
Read Request
Reply
Write Access
Reply
CB: Control byte
120
Minimum Frequency
COB ID CB
Index
601
40
46 60
581
43
46 60
601
23
46 60
581
60
46 60
SI: Sub Index All values in hexadecimal without leading 0x
CM-CAN ACU
418 and
Maximum Frequen-
1118.
Limitation
SI
Data
01
00 00 00 00
01
00 00 00 00
01
DC 05 00 00
01
00 00 00 00
04/13
Need help?
Do you have a question about the Vectron Active Cube and is the answer not in the manual?