15 14 13 12 11 10 9
NOTE
The mode "Move away from limit switch" works under normal conditions with hard-
ware limit switches. For Software limit switches the mode only works if a Software
limit switch
warning (in example "10-Warning") is selected, the software limit switch is not trig-
gering a fault and therefore the mode "Move away from limit switch" won't move
away from the software limit switch.
NOTE
The mode "Move away from Limit Switch" must not be used after one of the follow-
ing error messages occurred:
•
•
•
If one of these faults has occurred, the wiring and parameterization must be checkd
before the operation is continued.
212
8
7
1144 with reaction "error" is selected. If a setting with
Fault Reaction
F1444 Pos. SW Limit Switch < Neg. SW Limit Switch
F1445 Pos. and Neg. HW-Limit Switch Simultaneously
F1446 Limit Switch Incorrect Wired
CM-CAN ACU
Status word
6
5
4
3
2
1
0 Bit
10
11
12
13
14
15
0
Ready to switch on
1
Switched on
2
Operation enabled
3
Fault
4
Voltage enabled
5
Quick stop (Low active)
6
Switch on disabled
7
Warning
8
-
9
Remote
Target reached
Internal limit active
-
-
-
Warning 2
04/13