12.2.12 0x1011/n Restore default Parameters

Index Sub-index
0x1011
0
1
2
3
With object 0x1011/n parameters/objects can be set to their default values. This ob-
ject supports 3 sub-indexes with different functions.
Writing "load" to 0x1011/3 restores all application parameters (0x6nnn).
Specification of write "load" command
Writing a value other than "load" results in an SDO abort. The restore defaults com-
mand is not processed.
Example:
Read Request
Reply
Write Access
Reply
CB: Control byte
62
Meaning
Highest sub-index supported
Restore all parameters
Restore communication parame-
ters
Restore application parameters
LSB
"l"
"o"
0x6C
0x6F
COB ID CB
601
40
581
43
601
23
581
60
SI: Sub Index All values in hexadecimal without leading 0x
CM-CAN ACU
Data type
Unsigned8
Unsigned32
Unsigned32
Unsigned32
"a"
0x61
Index
SI
Data
11 10
01
00 00 00 00
11 10
01
01 00 00 00
11 10
01
6C 6F 61 64
11 10
01
00 00 00 00
Access
Map Def.-Val
ro
No
3
r/w
No
See text
r/w
No
See text
r/w
No
See text
MSB
"d"
0x64
04/13