4.
Use the Oracle ILOM faultmgmt shell to identify the faulty component.
See
"Identify Faulted Components" on page
Check the Fault class and Description fields for more information.
5.
If the drive backplane is faulty, replace it.
See
"Remove the Drive Backplane" on page
6.
If you are unable to determine if the drive backplane is faulty, seek more
information.
See
"Detecting and Managing Faults" on page
Related Information
"Preparing for Service" on page 43
■
"Remove the Drive Backplane" on page 119
■
"Detecting and Managing Faults" on page 25
■
Remove the Drive Backplane
Removing the drive backplane is a cold-service operation. You must power off the server before
you remove the drive backplane.
This procedure requires that you handle components that are sensitive to ESD, which
Caution -
can cause server components to fail.
Prepare for service.
1.
See
"Preparing for Service" on page
2.
Tilt and pivot the air filter away from the server.
See
"Remove the Filter" on page
Complete these prerequisites in this order.
3.
See:
"Remove a SAS Drive" on page 89
■
Remove all drives.
"Rotate the Drive Cage to the Service Position" on page 71
■
27.
119.
25.
43.
79.
Remove the Drive Backplane
Servicing the Drive Backplane
119