d.
Switch to the system console to view POST output.
Watch the POST output for possible fault messages. This output indicates that POST did
not detect any faults:
-> start /HOST/console
...
0:0:0>INFO:
0:0:0>
POST Passed all devices.
0:0:0>POST:
0:0:0>Master set ACK for vbsc runpost command and spin...
The server might boot automatically at this point. If so, go to
Note -
remains at the OpenBoot prompt (ok) go to the next step.
e.
If the server remains at the OpenBoot prompt, type boot.
f.
Return the virtual keyswitch to Normal mode.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
g.
Switch to the system console and type:
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in
Managing Faults" on page
4.
Switch to the Oracle ILOM command shell.
5.
Type:
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
Return to VBSC.
25.
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
Step
| Value
| /SYS/CMP0/MCU0/CH0/D0
| Mar 18 16:02:56
| SPSUN4V-8001-OJ
|
| 2782ad0c-91cb-c780-9663-807f0bf806df
Verify a DIMM
3f. If the server
"Detecting and
Servicing DIMMs
167