Oracle Netra SPARC S7-2 Service Manual page 168

Hide thumbs Also See for Netra SPARC S7-2:
Table of Contents

Advertisement

Verify a DIMM
faults/0
/SP/faultmgmt/0/
faults/0
If this command reports a fault with a UUID go to
fault with a UUID, you are done with the verification process.
6.
Switch to the system console and type the fmadm repair command with the UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show faulty
command. For example, type:
# fmadm repair 7c7efb20-3333-e2d7-b8ea-986b3e9dbaa9
Related Information
"Understanding DIMM Layout and Population Rules" on page 160
"Locate a Faulty DIMM" on page 161
"Remove a DIMM" on page 163
168
Netra SPARC S7-2 Server Service Manual • February 2017
|
| timestamp
|
|
| Mar 18 16:02:56
|
Step
6. If show faulty does not report a