Locate a Faulty Drive
Volumes
Expanders
Properties:
health = OK
health_details = -
...
->
If the health_details property identifies a faulty drive, replace it. See
Drive" on page
4.
Check the health of the individual drives.
-> show /System/Storage/Disks/Disk_x
/System/Storage/Disks/Disk_0
Targets:
Properties:
health = OK
health_details = -
...
->
where x is the number of the drive, from 0 to 7.
If the health_details property identifies the drive as faulty, replace it. See
Drive" on page
Verify that a drive is faulty.
5.
If a drive is faulty, you will see /SYS/DBP/HDDx under the Value heading, where x is 0 to 7.
For example, type:
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
...
->
If a drive is faulty, replace it.
See
"Remove a SAS Drive" on page
If a FRU value different from /SYS/DBP/HDDx is displayed, see
Reference" on page 47
6.
Use the Oracle ILOM faultmgmt shell to identify the faulty component.
See
"Identify Faulted Components" on page