Sign In
Upload
Manuals
Brands
Oracle Manuals
Server
X5-2L
Oracle X5-2L Manuals
Manuals and User Guides for Oracle X5-2L. We have
1
Oracle X5-2L manual available for free PDF download: Service Manual
Oracle X5-2L Service Manual (324 pages)
Brand:
Oracle
| Category:
Server
| Size: 33.28 MB
Table of Contents
Table of Contents
5
Using this Documentation
11
Product Documentation Library
11
Feedback
11
About the Oracle Server X5-2L
13
Product Description
13
About Controls and Connectors
14
Front Panel Components on Eight Drive Systems
14
Related Information
15
Front Panel Components on Twelve Drive Systems
16
Front Panel Components on Twenty-Four Drive Systems
17
Rear Panel Components and Cable Connections
18
About System Components
19
Illustrated Parts Breakdown
19
Customer-Replaceable Units
21
Field-Replaceable Units
22
Troubleshooting and Diagnostics
25
Troubleshooting Server Component Hardware Faults
25
Troubleshooting Server Hardware Faults
26
Troubleshooting and Diagnostic Information
29
Troubleshooting Using the Server Front and Rear Panel Status Indicators
30
Server Fan Status Indicators
32
Power Supply Status Indicators
33
Ethernet Ports Status Indicators
34
Motherboard Status Indicators
34
Troubleshooting System Cooling Issues
35
Troubleshooting Power Issues
37
Top Cover
38
Managing Server Hardware Faults through the Oracle ILOM Fault Management Shell
39
Troubleshooting with Diagnostic Tools
39
Diagnostic Tools
40
Diagnostic Tool Documentation
41
Attaching Devices to the Server
41
Attach Devices to the Server
42
Rear Panel Connector Locations
42
Configuring Serial Port Sharing
44
Server Operating System Names for the Nvme Storage Drives
45
Ethernet Port Boot Order and Device Naming
46
Rear Panel Pinhole Switches
47
Getting Help
48
Contacting Support
48
Related Information
49
Locating the Chassis Serial Number
49
Preparing for Service
51
Safety Precautions
51
Safety Symbols
52
Electrostatic Discharge Safety
52
FRU Key Identity Properties (KIP) Automated Update
53
Related Information
54
Required Tools
54
Preparing the Server for Component Replacement
54
Powering down the Server
55
Power Button
58
Disconnect Cables from the Server
60
Extend the Server to the Maintenance Position
61
Remove the Server from the Rack
63
Take Antistatic Measures
64
Remove the Server Top Cover
64
Remove the Fan Assembly Door from the Server
65
Remove the Disk Cage Cover from the Server
67
Servicing Crus that Do Not Require Server Power-Off
71
Servicing Storage Drives and Rear Drives (CRU)
71
Storage Drives Hot-Plug Conditions
72
Storage Drive Failure and RAID
72
Removing and Replacing an HDD or SSD Storage Drive
73
Removing and Replacing an Nvme Storage Drive Using Oracle Solaris
79
Removing and Replacing an Nvme Storage Drive Using Oracle Linux
82
Removing and Replacing a Rear Storage Drive
86
Servicing Fan Modules (CRU)
89
Remove a Fan Module
89
Install a Fan Module
92
Servicing Power Supplies (CRU)
93
Remove a Power Supply
94
Oracle Server X5-2L Service Manual • May
94
Install a Power Supply
97
Servicing Crus that Require Server Power-Off
101
Servicing the Dimms (CRU)
101
DIMM and Processor Physical Layout
102
DIMM Population Scenarios
103
DIMM Population Rules
104
Populating Dimms for Optimal System Performance
104
Populating Dimms in Single-Processor Systems for Optimal System Performance
105
Populating Dimms in Dual-Processor Systems for Optimal System Performance
106
DIMM Operating Speeds
108
DIMM Rank Classification Labels
108
Inconsistencies between DIMM Fault Indicators and the BIOS Isolation of Faulty Dimms
108
Using the Server Fault Remind Button
108
Identify and Remove a Faulty DIMM
109
Install a DIMM
113
Servicing Pcie Cards (CRU)
115
Pcie Slot Locations
116
Remove a Pcie Card
117
Install a Pcie Card
119
Servicing the Internal USB Flash Drives (CRU)
121
Servicing the Oracle System Assistant USB Flash Drive
122
Remove an Internal USB Flash Drive
122
Install an Internal USB Flash Drive
124
Servicing the Battery (CRU)
126
Remove the Battery
126
Install the Battery
128
Servicing Frus
129
Servicing Processors (FRU)
129
Selecting the Correct Processor Removal and Replacement Tool
130
Remove a Processor
134
Install a Processor
140
Servicing the Front and Rear Storage Drive Backplanes (FRU)
146
Remove the Storage Drive Backplane for Eight-Drive Systems
146
Install the Storage Drive Backplane for Eight-Drive Systems
149
Remove the Storage Drive Backplane for Twelve-Drive Systems
152
Install the Storage Drive Backplane for Twelve-Drive Systems
155
Remove the Storage Drive Backplane for Twenty-Four Drive Systems
158
Install the Storage Drive Backplane for Twenty-Four Drive Systems
160
Remove the Storage Drive Backplane for Rear-Mounted Storage Drives
162
Install the Storage Drive Backplane for Rear-Mounted Storage Drives
165
Servicing SAS Cables (FRU)
167
Remove SAS Storage Drive Cables
168
Install SAS Storage Drive Cables
171
Servicing Nvme Cables (FRU)
174
Related Information
175
Remove Nvme Cables
175
Install Nvme Cables
177
Servicing the Oracle Storage 12 Gb/S SAS Pcie RAID HBA Card (FRU)
180
Remove the Oracle Storage 12 Gb/S SAS Pcie RAID HBA Card
180
Install the Oracle Storage 12 Gb/S SAS Pcie RAID HBA Card
184
Servicing the DVD Drive (FRU)
187
Remove the DVD Drive
188
Install the DVD Drive
190
Servicing the Front LED/USB Indicator Modules (FRU)
193
Remove the Left LED Indicator Module
193
Install the Left LED Indicator Module
197
Remove the Right LED/USB Indicator Module
201
Install the Right LED/USB Indicator Module
205
Servicing the Motherboard Assembly (FRU)
209
Remove the Motherboard Assembly
209
Install the Motherboard Assembly
219
Returning the Server to Operation
225
Server Filler Panel Requirements
225
Remove and Install Filler Panels
226
Install the Server Top Cover
226
Install the Fan Assembly Door
228
Install the Disk Cage Cover
229
Remove Antistatic Measures
230
Reinstall the Server in the Rack
230
Return the Server to the Normal Rack Position
231
Reconnect Power and Data Cables
233
Power on the Server
233
Oracle Server X5-2L Service Manual • May
234
Identifying the Server Ports
235
Gigabit Ethernet Ports
235
Network Management Port
236
Serial Management Port
237
Video Connector
239
USB Ports
240
Setting up BIOS Configuration Parameters
241
Managing the BIOS Configuration
241
Accessing the BIOS Setup Utility
242
BIOS Setup Utility Menus
242
BIOS Key Mappings
243
Access BIOS Setup Utility Menus
243
Navigate BIOS Setup Utility Menus
245
Using UEFI
246
Selecting Legacy BIOS or UEFI Boot Mode
246
Switching between Legacy BIOS and UEFI Boot Modes
247
UEFI Boot Mode Advantages
247
Configuration Utilities for Add-In Cards
248
Using BIOS for Resource Allocation
248
Legacy Option ROM Allocation
249
Common BIOS Setup Utility Tasks
250
Verify BIOS Factory Default Settings
250
Select Legacy BIOS or UEFI BIOS Boot Mode
251
Select the Boot Device
252
Enable or Disable Oracle System Assistant
254
Configure TPM Support
256
Configure SP Network Settings
259
Configure Option ROM Settings
262
Configure I/O Resource Allocation
265
Exit BIOS Setup Utility
266
BIOS Setup Utility Menu Options
269
BIOS Main Menu Selections
269
BIOS Advanced Menu Selections
273
BIOS Advanced Menu Processor Configuration Options
274
BIOS Advanced Menu CPU Power Management Configuration Options
274
BIOS Advanced Menu Memory Configuration Option
275
BIOS Advanced Menu USB Ports Options
276
BIOS Advanced Menu Serial Port Console Redirection Options
276
BIOS Advanced Menu Trusted Computing Options
278
BIOS Advanced Menu Network Stack Options
279
BIOS Advanced Menu BMC Network Configuration Options
279
BIOS Advanced Menu Iscsi Configuration Options
282
BIOS Advanced Menu Ethernet Controller Options
284
BIOS IO Menu Selections
285
BIOS IO Menu PCI Subsystem Settings Options
286
BIOS IO Menu IO Virtualization Options
287
BIOS IO Menu I/OAT Configuration Options
287
BIOS IO Menu Internal Devices Options
288
BIOS IO Menu Add in Cards Options
288
BIOS Boot Menu Selections
289
BIOS Exit Menu Selections
290
Monitoring Components and Identifying SNMP Messages
293
Monitoring Component Health and Faults Using Oracle ILOM
293
Monitoring System Components
294
System Chassis Components
295
Cooling Unit Components
296
Disk Backplane Components
297
Memory Device Components
298
Power Unit Components
299
Processor Components
300
System Board Components
301
System Firmware Components
302
Hard Disk Drive Components
303
Identifying SNMP Trap Messages
304
Environmental Events
305
Hard Disk Drive Events
307
Power Events
307
Fan Events
311
Memory Events
312
Entity Presence Events
318
Physical Security Events
318
Index
319
Oracle Server X5-2L Service Manual • May
320
Advertisement
Advertisement
Related Products
Oracle netra X5-2
Oracle X5-4
Oracle EXADATA X5-8
Oracle X4 series
Oracle Database Appliance X6-2-HA
Oracle X7-8
Oracle X7 series
Oracle Sun Blade X6240
Oracle X9-2L
Oracle EXADATA X4-2L
Oracle Categories
Server
Storage
Network Hardware
Software
Controller
More Oracle Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL