Power Off the Server (Emergency Shutdown)
"Power Off the Server (Emergency Shutdown)" on page 52
■
Power Off the Server (Emergency Shutdown)
Caution -
changes. File system corruption and data loss might occur.
Press and hold the Power button for four seconds.
See
"Front Panel Components (Service)" on page
Related Information
"Prepare to Power Off a Server" on page 50
■
"Disconnect Power Cords and Data Cables" on page 52
■
"Power On the Server (Power Button)" on page 250
■
"Front Panel Components (Service)" on page 17
■
"Power Off the Server (Oracle ILOM)" on page 50
■
"Power Off the Server (Power Button - Graceful)" on page 51
■
Disconnect Power Cords and Data Cables
1.
When performing a cold-swap procedure, power off the server.
See:
"Power Off the Server (Oracle ILOM)" on page 50
■
"Power Off the Server (Power Button - Graceful)" on page 51
■
"Power Off the Server (Emergency Shutdown)" on page 52
■
Unplug all power cords from the server.
2.
Caution -
the power cords before accessing any cold-serviceable components.
For AC power cords.
■
52
Netra SPARC S7-2 Server Service Manual • February 2017
For this procedure, all applications and files are closed abruptly without saving
Because 12+ VDC standby power is always present in the system, you must unplug
17.