Oracle EAGLE Application B Card Hardware And Installation Manual

Table of Contents

Advertisement

Quick Links

Oracle Communications
EAGLE Application B Card
Hardware and Installation
910-6535-001 Revision D
February 2014

Advertisement

Table of Contents
loading

Summary of Contents for Oracle EAGLE Application B Card

  • Page 1 Oracle Communications EAGLE Application B Card Hardware and Installation 910-6535-001 Revision D February 2014...
  • Page 2 Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications.
  • Page 3: Table Of Contents

    Table of Contents Chapter 1: About This Manual ..............7 Introduction............................8 Where to Find Information in This Manual..................8 Programs Needed to View Linked Documents ..............9 Applications Documents......................9 Related Publications..........................9 Documentation Availability, Packaging, and Updates..............9 Locate Product Documentation on the Customer Support Site............10 Documentation Admonishments.......................10 Customer Care Center.........................11 Problem Report (PR)........................13...
  • Page 4 Chapter 4: Installing and Removing E5-APP-B Cards......38 Introduction............................39 Provisioning Rules for E5-APP-B Cards...................39 E5-APP-B Fan Alarms......................39 IMT Bus............................39 E5-APP-B Power Guidelines....................40 Obtaining the EAGLE Power Calculator................40 E5-APP-B Card Distance Limitations..................40 Installing an E5-APP-B Card......................41 Removing an E5-APP-B Card......................44 E5-APP-B Card Adapter Interfaces....................46 Changing Passwords...........................47 Appendix A: ExAP or LSMS Network Integration.......48 Introduction............................49...
  • Page 5 List of Figures Figure 1: E5-APP-B Card Label Locations....................18 Figure 2: Drive Module Label Locations......................19 Figure 3: European Directives CE Mark.......................23 Figure 4: Combined UL Mark for the United States and Canada.............23 Figure 5: Hazardous Substances........................24 Figure 6: Door Grounding Strap Placement....................28 Figure 7: E5-APP-B Card In Shelf........................31 Figure 8: E5-APP-B Card..........................32 Figure 9: E5-APP-B Card Indicators......................33...
  • Page 6 List of Tables Table 1: Manual Organization..........................8 Table 2: Admonishments..........................10 Table 3: Basic RMA Types..........................15 Table 4: RMA Reasons for Return........................15 Table 5: Space Requirements..........................26 Table 6: E5-APP-B Card Interfaces .......................35 Table 7: E5-APP-B LED Table.........................36 Table 8: EPAP Interconnect Table........................51 Table 9: ELAP Interconnect Table........................53 910-6535-001 Revision D, February 2014...
  • Page 7: Chapter 1: About This Manual

    Chapter About This Manual This chapter describes how to use the manual, where Topics: to find other information about this product, and Introduction..8 Customer Care Center. how to contact the Where to Find Information in This Manual..8 Related Publications..9 Documentation Availability, Packaging, and Updates..9 Locate Product Documentation on the Customer Support Site..10...
  • Page 8: Introduction

    About This Manual Introduction The Oracle Communications EAGLE Application B Card (E5-APP-B) is a complete application server platform designed to operate within a heavy duty EAGLE shelf. An E5-APP-B card consists of the card, a microprocessor, 8 GB RAM, and two removable drive modules with an operating system and an application, such as EPAP, loaded.
  • Page 9: Programs Needed To View Linked Documents

    Hardware and Installation Manual About This Manual Optionally, the DVD may also contain application documentation, which describes the environment in which the E5-APP-B card runs and provides information about the application. Programs Needed to View Linked Documents Linked documents are in Portable Document Format (PDF), which has a file type of .pdf. PDF is also the format of this manual.
  • Page 10: Locate Product Documentation On The Customer Support Site

    Hardware and Installation Manual About This Manual Documentation is updated when significant changes are made that affect system operation. Updates resulting from Severity 1 and 2 Problem Reports (PRs) are made to existing manuals. Other changes are included in the documentation for the next scheduled release. Updates are made by re-issuing an electronic file to the customer support site.
  • Page 11: Customer Care Center

    Hardware and Installation Manual About This Manual Icon Description Caution: (This icon and text indicate the possibility of service interruption.) Topple: (This icon and text indicate the possibility of personal injury and equipment damage.) Customer Care Center The Tekelec Customer Care Center is your initial point of contact for all product support needs. A representative takes your call or email, creates a Customer Service Request (CSR) and directs your requests to the Tekelec Technical Assistance Center (TAC).
  • Page 12 Hardware and Installation Manual About This Manual Phone: 0-800-555-5246 (toll-free) Brazil Phone: 0-800-891-4341 (toll-free) TAC Regional Support Office Hours: 8:00 a.m. through 5:48 p.m. (GMT minus 3 hours), Monday through Friday, excluding holidays Chile Phone: 1230-020-555-5468 Colombia Phone: 01-800-912-0537 Dominican Republic Phone: 1-888-367-8552 Mexico...
  • Page 13: Problem Report (Pr)

    Hardware and Installation Manual About This Manual +44 1784 467 804 (within UK) Software Solutions Phone: +33 3 89 33 54 00 Asia India Phone: +91-124-465-5098 or +1-919-460-2150 TAC Regional Support Office Hours: 10:00 a.m. through 7:00 p.m. (GMT plus 5 1/2 hours), Monday through Saturday, excluding holidays Singapore Phone:...
  • Page 14: Emergency Response

    Hardware and Installation Manual About This Manual Any loss of functional visibility and/or diagnostic capability Short outage equivalent to system or subsystem outages, with accumulated duration of greater than two minutes in any 24-hour period, or that continue to repeat during longer periods Repeated degradation of DS1 or higher rate spans or connections Prevention of access for routine administrative activity Degradation of access for maintenance or recovery operations...
  • Page 15: Hardware Repair And Return

    Hardware and Installation Manual About This Manual Hardware Repair and Return Any system components being returned for repair or replacement must be processed through the Tekelec Return Material Authorization (RMA) procedures. A hardware repair is defined as an item returned to Tekelec due to a failure, with the returned item being repaired and returned to the customer. It is essential that serial numbers are recorded correctly.
  • Page 16: Repair And Return Shipping Instructions

    Hardware and Installation Manual About This Manual Reason for Return Description Product Recall Products recalled by divisions for the repair of a defect or replacement of defective products. Return – No Product Deficiency Anything returned without the product being defective. Repair and Return Shipping Instructions All returned equipment, assemblies, or subassemblies must be shipped to the Tekelec Repair and Return Facility specified by the...
  • Page 17: Locating E5-App-B Card Part Numbers

    Hardware and Installation Manual About This Manual Reason for return or replacement (isolated from system): Full name of person the replacement card is being shipped to: Shipping address: Note: If possible, include associated alarms (UAMs) and a copy of the associated output (capture file).
  • Page 18: Figure 1: E5-App-B Card Label Locations

    Hardware and Installation Manual About This Manual To locate the part number information, use the indicated procedure below: E5-APP-B card, use Locating E5-APP-B Card Part Number Information Drive module assembly, use Locating Drive Module Assembly Part Number Information Locating E5-APP-B Card Part Number Information The part number information for the E5-APP-B card is located on the label on the faceplate of the E5-APP-B card.
  • Page 19: Figure 2: Drive Module Label Locations

    Hardware and Installation Manual About This Manual 1. Request that the Customer Care Center assist you in determining whether the drive module assembly that needs to be replaced is in drive A or drive B. 2. Find the part number information on the drive module. See Figure 2: Drive Module Label Locations for illustration.
  • Page 20: Chapter 2: Safety And Pre-Installation Requirements

    Chapter Safety and Pre-Installation Requirements This chapter lists general safety instructions that Topics: readers should be familiar with and site Introduction..21 requirements that should be verified before Safety Information..21 installing Tekelec E5-APP-B cards into an EAGLE shelf. Regulatory Compliance and Certification..22 Pre-Installation Site Requirements..24 910-6535-001 Revision D, February 2014...
  • Page 21: Introduction

    Hardware and Installation Manual Safety and Pre-Installation Requirements Introduction This chapter presents general safety considerations to be kept in mind when installing or replacing Tekelec products, a listing of regulatory compliance statements and certifications that Tekelec products support, and site requirements for installing Tekelec products. Safety Information Safety icons and text are used throughout Tekelec manuals to warn the reader of the potential of personal injury, service interruption, and equipment damage.
  • Page 22: Regulatory Compliance And Certification

    Hardware and Installation Manual Safety and Pre-Installation Requirements Warning: Do not allow any metal shavings to remain in the equipment area. Metal Shavings may result from over tightened screws or bolts. These small metal particles are hazardous to electronic equipment. Be careful not to over tighten screws or bolts. Warning: Do not use tie wraps on or above the top traverse arms on a frame.
  • Page 23: Figure 3: European Directives Ce Mark

    Hardware and Installation Manual Safety and Pre-Installation Requirements Network Equipment Building System (NEBS) level 3 as listed in Telcordia SR-3580. Applicable Telcordia Electromagnetic Compatibility and Electrical Safety requirements in GR-1089-CORE. Applicable Physical Protection requirements in GR-63-CORE. Relevant directives and harmonized standards in support of the products Compliance European (CE) mark required in Europe.
  • Page 24: Pre-Installation Site Requirements

    Hardware and Installation Manual Safety and Pre-Installation Requirements Figure 5: Hazardous Substances Pre-Installation Site Requirements Before installing E5-APP-B cards into an EAGLE shelf, make sure that the requirements described in both of the following sections have been met. Generic Site Requirements Grounding and Power Requirements Generic Site Requirements Ensure that the site where the product will be installed conforms to the specifications listed in the...
  • Page 25 Hardware and Installation Manual Safety and Pre-Installation Requirements Environmental Requirements Tekelec products are designed for environments that have temperature and humidity controls. Temperature and humidity controls must be activated as quickly as possible for equipment to operate at an optimum level. When temperature and humidity controls fail, the equipment has been tested to operate within the following ranges: Temperature...
  • Page 26: Table 5: Space Requirements

    Hardware and Installation Manual Safety and Pre-Installation Requirements Earthquake Resistance All Tekelec system configurations are designed to assure that the system remains operational during and after an earthquake, even when the system is located on the upper floors of a zone 4 central office. Space Requirements Provide space as described in Generic Site...
  • Page 27: Grounding And Power Requirements

    Hardware and Installation Manual Safety and Pre-Installation Requirements Grounding and Power Requirements Before installing E5-APP-B cards into an EAGLE shelf, make sure that the grounding and power requirements in the appropriate following sections have been met. Grounding Requirements EAGLE Shelf Power Requirements Grounding Requirements Tekelec systems operate as digital isolated ground plane systems in a central office environment and require a single connection to the central office ground window.
  • Page 28: Figure 6: Door Grounding Strap Placement

    Hardware and Installation Manual Safety and Pre-Installation Requirements Figure 6: Door Grounding Strap Placement EAGLE Shelf Power Requirements E5-APP-B cards use power resources of the frame in which the EAGLE shelf is installed. Each card is fused at 3A. There is detailed information in the Power Calculator spreadsheet available on the Tekelec Customer Support site.
  • Page 29: Chapter 3: E5-App-B Card Overview

    Chapter E5-APP-B Card Overview This chapter presents an overview of the E5-APP-B Topics: card package, components, and adapter interfaces. Introduction..30 E5-APP-B Card..30 E5-APP-B Card Features..31 E5-APP-B Card Components..34 E5-APP-B Card Interfaces..34 Electrical Features..35 Mechanical Design and Maintenance Features..35 E5-APP-B Card Diagnostics..36 910-6535-001 Revision D, February 2014...
  • Page 30: Introduction

    Hardware and Installation Manual E5-APP-B Card Overview Introduction E5-APP-B card packages are designed to be integrated with features that run on a Signal Transfer Point (STP). E5-APP-B cards for these applications run in a Direct Current (DC) environment and are delivered as a pair to be installed in an EAGLE using heavy duty frames, along with breaker panels and Ethernet communication equipment.
  • Page 31: E5-App-B Card Features

    Hardware and Installation Manual E5-APP-B Card Overview Figure 7: E5-APP-B Card In Shelf E5-APP-B Card Features A single E5-APP-B card is a general-purpose application server (AS) that offers high transaction rates with low latency. It supports a variety of application solutions for the wireless and wireline telecommunications infrastructure to provide the building blocks for next-generation signaling systems.
  • Page 32: Figure 8: E5-App-B Card

    Hardware and Installation Manual E5-APP-B Card Overview Figure 8: E5-APP-B Card The following are Field Replaceable Units: E5-APP-B card (1) Drive Module (4) For more information about FRUs, see the corresponding Alarms and Maintenance manual included in this release. The other features components are: Injector/Ejector (2) Ejector Switch (3) Drive module locking switch (5)
  • Page 33: Figure 9: E5-App-B Card Indicators

    Hardware and Installation Manual E5-APP-B Card Overview E5-APP-B Card Status Indicators Figure 9: E5-APP-B Card Indicators The following light-emitting diode (LED) status indicators (see Figure 9: E5-APP-B Card Indicators) can be found on the E5-APP-B card: 910-6535-001 Revision D, February 2014...
  • Page 34: E5-App-B Card Components

    Hardware and Installation Manual E5-APP-B Card Overview One Server Status indicator (A) Four E-Net link and Active LED status indicators (B) Two drive module status indicators (C) One Card Eject status indicator (D) For more information about the diagnostics that manage these alarm and status indicators, see E5-APP-B Card Diagnostics.
  • Page 35: Electrical Features

    Hardware and Installation Manual E5-APP-B Card Overview Table 6: E5-APP-B Card Interfaces Interface Description Four Serial interfaces Standard RS-232D serial interfaces are usually used for connecting to other equipment. The Serial interfaces are accessed via backplane adapters. One USB port - For software upgrades One Universal Serial Bus (USB) port to support direct connectivity to peripherals.
  • Page 36: E5-App-B Card Diagnostics

    Hardware and Installation Manual E5-APP-B Card Overview E5-APP-B Card Diagnostics All components that comprise the E5-APP-B card platform are designed for testability to ensure that operational status can be accurately determined and that appropriate levels of fault detection and isolation are possible with a minimum of effort. The following levels of diagnostics are provided: 1.
  • Page 37 Hardware and Installation Manual E5-APP-B Card Overview LED Name HW/SW Controlled Description Act LED B2 Flashing Green - Link Activity Link LED A1 Green - 10/100 Link Speed Amber - 1000 Link Speed Link LED A2 Green - 10/100 Link Speed Amber - 1000 Link Speed Link LED B1 Green - 10/100 Link Speed...
  • Page 38: Chapter 4: Installing And Removing E5-App-B Cards

    Chapter Installing and Removing E5-APP-B Cards This chapter covers provisioning rules and Topics: installation and removal procedures for the Introduction..39 E5-APP-B cards. Provisioning Rules for E5-APP-B Cards..39 Installing an E5-APP-B Card..41 Removing an E5-APP-B Card..44 E5-APP-B Card Adapter Interfaces..46 Changing Passwords..47 910-6535-001 Revision D, February 2014...
  • Page 39: Introduction

    E5-APP-B based Oracle Communications EAGLE LNP Application Processor (ELAP) or EAGLE Application Processor Provisioning (EPAP) systems do not support DSM cards (870-1984-xx). DSM cards must be replaced with Oracle Communications EAGLE Service Module (E5-SMxG) cards. E5-APP-B Fan Alarms E5-APP-B cards that are being deployed in a remote EAGLE shelf or in EAGLE shelf 6200 or 6300 will have adapters and fan alarm cables installed so the application will receive Fan Alarms through the application Graphical User Interface (GUI).
  • Page 40: E5-App-B Power Guidelines

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards The E5-APP-B card must be provisioned and its power consumption specified when the card is installed in any slot in the 1100 through 6300 shelves so that its power consumption may be included with the EAGLE Power Calculations.
  • Page 41: Installing An E5-App-B Card

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Installing an E5-APP-B Card To install an E5-APP-B card into an EAGLE shelf: Note: The E5-APP-B Card should arrive in the LOCKED state. If it arrives UNLOCKED, skip to step 1. On the E5-APP-B card, slide the Ejector switch (4) up to the UNLOCKED position. See Figure 10: E5-APP-B Card Inject Hardware Switch, UNLOCKED.
  • Page 42: Figure 11: E5-App-B Card Unlocked

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Figure 11: E5-APP-B Card UNLOCKED 4. Insert the E5-APP-B card into the EAGLE shelf. 910-6535-001 Revision D, February 2014...
  • Page 43: Figure 12: E5-App-B Card Inject Levers

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Carefully align the edges of the card with the top and bottom card guides. Then, push the card along the length of the card guides until the rear connectors on the card engage the mating connectors on the target shelf backplane.
  • Page 44: Removing An E5-App-B Card

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Figure 13: E5-APP-B Card Inject Hardware Switch, LOCKED 7. WAIT for the E5-APP-B Eject Status LED to go from blinking red to off. Removing an E5-APP-B Card Procedure - Remove E5-APP-B card Refer to the Hardware and Installation manual for E5-APP-B on halting the E5-APP-B Card software.
  • Page 45: Figure 14: E5-App-B Card Eject Hardware Switch, Unlocked

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Figure 14: E5-APP-B Card Eject Hardware Switch, UNLOCKED 2. WAIT for the E5-APP-B Eject Status LED to go from blinking red to a steady red. 3. Grasp the upper and lower card Inject/Eject (I/E) lever release (3) just underneath the I/E lever, and press it to meet the I/E lever.
  • Page 46: E5-App-B Card Adapter Interfaces

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Figure 15: E5-APP-B Card UNLOCKED 4. While holding the I/E interlock and lever, pull the levers (2) away from the shelf until they are parallel to the floor. 5. Remove the E5-APP-B card from the EAGLE shelf. E5-APP-B Card Adapter Interfaces The E5-APP-B card supports an upper and a lower backplane adapter, which supports the following interfaces:...
  • Page 47: Changing Passwords

    Hardware and Installation Manual Installing and Removing E5-APP-B Cards Fan alarm Changing Passwords For security purposes, Tekelec recommends that all default passwords be changed and kept in a secure location. To change the passwords for E5-APP-B platforms, refer to the application manual for the application loaded on each server.
  • Page 48: Appendix A: Exap Or Lsms Network Integration

    Appendix ExAP or LSMS Network Integration This chapter provides network integration Topics: information for Multi-Purpose Server (MPS) systems Introduction..49 and Oracle Communications LSMS (Local Service Network Overview..49 Management Systems). Customer-Supplied Information..54 Network Configuration..54 Firewall and Router Filtering Considerations..54 910-6535-001 Revision D, February 2014...
  • Page 49: Introduction

    ExAP or LSMS Network Integration Introduction The MPS platform can be configured as an Oracle Communications EAGLE LNP Application Processor (ELAP) or EAGLE Application Processor Provisioning (EPAP) server. The MPS platform is an ELAP/EPAP system based on the E5-APP-B card platform.
  • Page 50: Figure 16: Epap Network Connections

    Hardware and Installation Manual ExAP or LSMS Network Integration Figure 16: EPAP Network Connections A. Adapter installed in the Upper position, odd slot B. Adapter installed in the Lower position, odd slot C. Adapter installed in the Lower and Upper position, even slot D.
  • Page 51: Table 8: Epap Interconnect Table

    Hardware and Installation Manual ExAP or LSMS Network Integration Table 8: EPAP Interconnect Table Cable Part Number From 830-1173-68 CAT 5 Crossover Switch A port 1 Switch B port 1 830-1173-68 Cat 5 Crossover Switch A port 2 Switch B port 2 830-1220-XX Serial Roll Over Card / Server A, (P3) Card /Server B, (P4)
  • Page 52 Hardware and Installation Manual ExAP or LSMS Network Integration 830-1413-XX Card Server A (P2) 830-1407-XX Eagle Backplane Fan Connector (J2 B) 830-1410-XX 830-1413-XX Card Server B (P2) 830-1407-XX Eagle Backplane Fan Connector (J3 A) 830-1410-XX 830-1212-XX Card Server B (P5) Eagle MMI Port Optional Cable, requires adapter 830-1423-XX 910-6535-001 Revision D, February 2014...
  • Page 53: Figure 17: Elap Network Connections

    Hardware and Installation Manual ExAP or LSMS Network Integration Figure 17: ELAP Network Connections Table 9: ELAP Interconnect Table Cable Part Number From 830-1173-68 CAT 5 Crossover Switch A port 1 Switch B port 1 830-1173-68 Cat 5 Crossover Switch A port 2 Switch B port 2 830-1220-XX Serial Roll Over Card / Server A, (P3)
  • Page 54: Customer-Supplied Information

    Hardware and Installation Manual ExAP or LSMS Network Integration Customer-Supplied Information The customer’s network administrator provides the following information: Two IP addresses on the provisioning network Netmask of the provisioning network Default router on the provisioning network Network Configuration SM and Sync Network addresses are configured to default values at ExAP or LSMS initialization and should not need to be changed.
  • Page 55: Glossary

    Glossary Alternating Current Application Context Authentication Center Area Code ANSI American National Standards Institute An organization that administers and coordinates the U.S. voluntary standardization and conformity assessment system. ANSI develops and publishes standards. ANSI is a non-commercial, non-government organization which is funded by more than 1000 corporations, professional bodies, and enterprises.
  • Page 56 Hardware and Installation Manual Glossary Authentification servers provide public access to certificates, and are integrated with electronic information retrieval systems to this end. Free access to certificates is necessary to support authentication in open systems. Application Simulator Test tool that can simulate applications and/or SMSCs.
  • Page 57 Hardware and Installation Manual Glossary ELAP EAGLE Local Number Portability Application Processor The EAGLE LNP Application Processor (ELAP) platform provides capacity and performance required to support the ported number database. EPAP EAGLE Provisioning Application Processor Electro-Static Discharge Field Replaceable Unit A circuit board or part that can be quickly and easily removed and replaced by the user or by a...
  • Page 58 Hardware and Installation Manual Glossary Local Area Network A private data network in which serial transmission is used for direct data communication among data stations located in the same proximate location. LAN uses coax cable, twisted pair, or multimode fiber. See also STP LAN.
  • Page 59 Hardware and Installation Manual Glossary A measure of a message processor’s performance capacity. A message is any Diameter message (Request or Answer) which is received and processed by a message processor. MTBF Mean Time Between Failures NEBS Network Equipment Building Systems The most common set of safety, spatial and environmental design...
  • Page 60 Hardware and Installation Manual Glossary Short Message Signal Transfer Point The STP is a special high-speed switch for signaling messages in SS7 networks. The STP routes core INAP communication between the Service Switching Point (SSP) and the Service Control Point (SCP) over the network.

This manual is also suitable for:

E5-app-b

Table of Contents