Oracle Netra SPARC S7-2 Service Manual page 133

Hide thumbs Also See for Netra SPARC S7-2:
Table of Contents

Advertisement

2.
Visually inspect the power supplies to see if any of their status LEDs are lit or
flashing.
See
"Power Supply LEDs" on page
3.
In Oracle ILOM, check the health of the power system.
-> show /System/Power
/System/Power
Targets:
Properties:
health = OK
health_details = -
...
->
If the health_details property identifies a faulty power supply, replace it. See
Power Supply" on page
Check the health of the individual power supplies.
4.
-> show /System/Power/Power_Supplies/Power_Supply_x
/System/Power/Power_Supplies/Power_Supply_0
Targets:
Properties:
health = OK
health_details = -
...
->
where x is either 0 (lower power supply) or 1 (upper power supply).
If the health_details property identifies the power supply as faulty, replace it. See
Power Supply" on page
Determine if a power supply is faulty.
5.
For example, type:
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
...
->
If a FRU value different from /SYS/PSx is displayed, see
Reference" on page 47
132.
134.
134.
| Property
| fru
to identify which component is faulty.
Locate a Faulty Power Supply
| Value
| /SYS/PS0
"Component Service Task
Servicing Power Supplies
"Remove a
"Remove a