Server Fault Remind Button Operation - Oracle Netra SPARC S7-2 Service Manual

Hide thumbs Also See for Netra SPARC S7-2:
Table of Contents

Advertisement

Clearing a fault with the fmadm aquit command does not clear that fault in the Oracle
Enterprise Manager Ops Center software. You must manually clear the fault or incident. For
more information, refer to Oracle Enterprise Manager Ops Center Feature Reference Guide at:
http://www.oracle.com/pls/topic/lookup?ctx=oc122
If you are servicing a component, return to the procedure for that component.
6.
Related Information
"Checking for Faults" on page 25
"Performing Advanced Troubleshooting" on page 34

Server Fault Remind Button Operation

When you press the server Fault Remind button, an LED located next to the Fault Remind
button lights green to indicate that there is sufficient voltage present in the fault remind circuit
to light any fault LEDs that were lit due to a component failure. If this LED does not light when
you press the Fault Remind button, it is likely that the capacitor powering the fault remind
circuit has lost its charge. This can happen if the Fault Remind button is pressed for several
minutes with fault LEDs lit or if power has been removed from the server for more than 15
minutes.
Fault LEDs are provided on the motherboard for DIMMs. The figure shows the location of the
Fault Remind button and LED.
Server Fault Remind Button Operation
Detecting and Managing Faults
41