Configure POST
/HOST/diag : Manage Host Power On Self Test Diagnostics
Targets:
Properties:
default_level : Diag level in the default cause (no error or hw change)
default_level : Possible values = off, min, max
default_level : User role required for set = r
default_verbosity : Diag verbosity in the default cause (no error or hw
default_verbosity : Possible values = none, min, normal, max
default_verbosity : User role required for set = r
error_level : Diag level when running after an error reset
error_level : Possible values = off, min, max
error_level : User role required for set = r
error_verbosity : Diag verbosity when running after an error reset
error_verbosity : Possible values = none, min, normal, max
error_verbosity : User role required for set = r
hw_change_level : Diag level when running after a hw change
hw_change_level : Possible values = off, min, max
hw_change_level : User role required for set = r
hw_change_verbosity : Diag verbosity when running after a hw change
hw_change_verbosity : Possible values = none, min, normal, max
hw_change_verbosity : User role required for set = r
->
Note -
status for extended periods of time on certain configurations.
3.
(Optional) Set the virtual keyswitch to determine the diagnostic level after an
error reset and after a hardware change.
To set error_level, to max, and to set hw_change_level to max, type:
-> set /HOST/diag error_level=max
-> set /HOST/diag hw_change_level=max
Refer to the section on setting the SPARC host keyswitch state in the Oracle ILOM
Administrator's Guide for Configuration and Maintenance Firmware Release 3.2.x for a
description of parameters and values.