If the DIMM does not easily seat into the connector socket, verify that the notch in the
DIMM is aligned with the connector key in the connector socket. If the notch is not
aligned, damage to the DIMM might occur.
3.
Replace the air baffle.
4.
(Optional) Use Oracle ILOM to clear server DDR4 DIMM faults.
DDR4 DIMM faults are automatically cleared after a new DIMM has been installed. If you
need to manually clear DDR4 DIMM faults, refer to the Oracle Integrated Lights Out Manager
(ILOM) 3.2 Documentation Library at http://www.oracle.com/goto/ILOM/docs.
Return the server to operation.
5.
See
"Returning a Server to Operation" on page
6.
Verify the DIMM.
See
"Verify a DIMM" on page
Related Information
"Understanding DIMM Layout and Population Rules" on page 160
"Locate a Faulty DIMM" on page 161
"Remove a DIMM" on page 163
235.
166.
Install a DIMM
Servicing DIMMs
165