Alarm Report Example:
The report example below shows an alarm for all busy Station and Trunk DSPs.
<< ALARM REPORT >>
LVL NO STAT
-------------------------------------------------------------------------------
MAJ 0068 ERR 01/22/09 09:30 VoIP All DSP Busy
MAJ 0068 ERR 01/22/09 09:31 VoIP All DSP Busy
MIN 0002 REC 01/22/09 09:32 PKG Installation
LCD Display
Clock/Calendar
VoIP DSP All Busy XX
Soft Key
Clock/Calendar
VoIP DSP All Busy YY-XX
Soft Key
S
2
S
ECTION
ERVICE
12-2
DATE
TIME
LCD Display Indication
C
ONDITIONS
When using IP Phones, the alarm is shown on both terminals involved in that call if
they are both on the same system, this includes NetLink systems.
The alarm cannot be displayed on Standard SIP Phones, Soft Phones or Single
Line phones.
If a call from a Standard SIP telephone to a Multiline telephone cannot be
established due to an All DSP Busy condition, the Multiline telephone will not
display the "All DSP" busy message.
If a SIP trunk call is sent to the SV9100 when all DSP resources are busy, the call is
rejected but the alarm is not displayed on any system telephone.
The default alarm setting is Minor.
If an all DSP condition is encountered when making a call across a CCISoIP
Network, only the calling stations receives the alarm indication.
01/22/2009 23:37
ITEM
UNIT
VoIPDB
VoIPDB
PRIU
Non-NetLink System
XX = Slot number of CCPU with IPLE blade.
NetLink System
YY = System ID
XX = Slot number of CCPU with IPLE blade.