Forced Change Primary System - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

7.1
10-36
51-06-02 : NetLink Primary System Automatic Integration Setting – Blade Reset
Timing Option
When the Primary Automatic Integration reestablishes the NetLink network, the
blades in the secondary SV9100s are reset. This option determines if the
secondary SV9100 blades are reset only when all blades are idle (0) or anytime
(1).
51-09-05 : NetLink TCP Port Settings – Primary Detection Port
Enter the port number to search for the Top Priority Primary SV9100. If 0 is
entered, the port is selected dynamically (0~65535).

Forced Change Primary System

If you need to change the Primary System, you can specify the communication
server manually. While the Top Priority Primary System is running, this feature is
not available. To use this feature, define the IP address or System ID of the target
communication server. From telephone programming, the user can change the
Primary System. When a new Primary System is manually selected, for the IP
terminals to reregister to the new Primary, the existing Primary System must be
powered down and then powered up.
Related Programming:
51-05-06 : Timer Settings for NetLink – Primary System Seeking Time with
Forced Change Primary
When the Forced Change Primary command is executed, the SV9100 searches
for the new Primary SV9100 for this time (1~10800).
51-06-02 : NetLink Primary System Automatic Integration Setting – Blade Reset
Timing Option
When the Primary Automatic Integration reestablishes the NetLink network, the
blades in the secondary SV9100s are reset. This option determines if the
secondary SV9100 blades are reset only when all blades are idle (0) or anytime
(1).
51-07-01 : NetLink Forced Change of Primary System Settings - Allow Forced
Change of Primary System
When Fail-Over occurs, you can manually change the Primary SV9100 using
Program 51-08, if this option is enabled. Program 51-06-01 must be set to "0".
51-07-02 : NetLink Forced Change of Primary System Settings – Blade Reset
Timing Option
When the Forced Change of Primary Settings is performed, the blades in the
secondary communication servers are reset. This option determines if the
secondary SV9100 blades are reset only when all blades are idle (0) or anytime
(1).
51-08-01 : New Primary System Setting – Internet Protocol Address of New
Primary
When forcing the communications server to update to a new Primary SV9100,
the communications server uses the IP address defined here as the new
Primary.
After a Forced Change of Primary SV9100 is done, this entry is erased.
Issue 2.0
SV9100 NetLink

Advertisement

Table of Contents
loading

Table of Contents