Sip Mlt Quick Startup Guide - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
Program
Program Name
Number
DT800/DT700
Multiline CODEC
Basic Information
84-24-35
Setup
G.722 Jitter Buffer
Average
DT800/DT700
Multiline CODEC
Basic Information
84-24-36
Setup
G.722 Jitter Buffer
Maximum
DT800/DT700
Multiline Firmware
84-28-01
Name Setup –
Firmware Directory
DT800/DT700
Multiline Firmware
84-28-02
Name Setup –
Firmware File Name

15.8 SIP MLT Quick Startup Guide

SV9100 Networking Manual
Description/Comments
Average value of the dynamic jitter
buffer.
Maximum value of the dynamic jitter
buffer.
Maximum 64 characters.
Maximum 30 characters.
The following guides describe the setup for a SIP MLT from a default state for
these modes:
Plug and Play
Automatic Registration
Manual Registration
15.8.1 Plug and Play
1.
Program 10-12
Assign the IPLE registration/signaling IP address, subnet mask, and
default gateway. If no customer provided default gateway is provided,
Assigned Data
Range: 0 ~ 300ms
Default is 60
Range: 0 ~ 300ms
Default is 120
Default is No Setting