NEC Univerge SV9100 Manual page 714

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
16-02 : Department Group Assignment for Extensions
Level:
IN
Description
Use Program 16-02 : Department Group Assignment for Extensions to set the Department Groups.
The system uses these groups (64 Department Groups) for Department Calling. Assign pilot numbers to
Department Groups you set up in Program 11-07. This lets system users place calls to the departments.
Use Program 16-01 to set the priority of each extension in each Department Group. When a call comes
to the group, the extensions ring in order of their priority.
Input Data
Item
No.
01
Conditions
None
Feature Cross Reference
Department Calling
SV9100 Networking Manual
Program 16 : Department Group Setup
Extension Number
Group
Priority
Number
1~64
1~999
The initial value of a priority becomes the ports numerical order assigned in Program 11-02 and 11-04.
(Extension ports are 1~ 960. Virtual extension ports are 961~1472.)
Default
Description
1 – xxx
Set up the Department Group called
(See
by the pilot number and the extension
Note)
priority when a group is called.
Call Pickup Groups are set up in
23-02.
Maximum eight digits
Related
Program
11-07
16-01
13-119

Advertisement

Table of Contents
loading

Table of Contents