Closed Number Programming Example - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
1.6
SV9100 Networking Manual

Closed Number Programming Example

This section provides the steps needed to program a closed numbering plan.
Step 1: T1 Tie Lines
The following diagram is an example of Programs that should be assigned for T1
Tie lines. The example assumes that the
GCD-CCTA card installed.
Abbreviations used in the diagram:
MB = Memory Block
CC = Clear Channel
PRG 10-03-03
CC = B8ZS
PRG 10-03-05
Internal
PRG 22-02-01
TT = E&M
PRG 14-05-01
TRK 001~024 = TG 10
PRG 14-01-13
TRK 001~024 = Yes
PRG 34-01-01
TRK 001~024 = Wink
PRG 11-01-01
1X = 3 digit; Intercom
2X = 3 digit; F-Route
3X = 3 digit; F-Route
PRG 11-02-01
Extensions = 1XX
PRG 11-04-01
Unassign Virtuals = 2XX
SV9100
TRK = Trunk
TT = Trunk Type
PRG 10-03-03
CC = B8ZS
PRG 10-03-05
External
Internal
PRG 22-02-01
TT = E&M
PRG 14-05-01
TRK 001~024 = TG 10
TRG 025~048 = TG 11
PRG 14-01-13
TRK 001~048 = Yes
PRG 34-01-01
TRK 001~048 = Wink
PRG 11-01-01
1X = 3 digit; F-Route
2X = 3 digit; Intercom
3X = 3 digit; F-Route
PRG 11-02-01
Extensions = 2XX
PRG 11-04-01
Unassign Virtuals = 2XX
system is defaulted with the
TG = Trunk Group
PRG 10-03-03
CC = B8ZS
PRG 10-03-05
External
PRG 22-02-01
TT = E&M
PRG 14-05-01
TRK 001~024 = TG 10
PRG 14-01-13
TRK 001~024 = Yes
PRG 34-01-01
TRK 001~024 = Wink
PRG 11-01-01
1X = 3 digit; F-Route
2X = 3 digit; F-Route
3X = 3 digit; Intercom
PRG 11-02-01
Extensions = 3XX
PRG 11-04-01
Unassign Virtuals = 2XX
3-7