1.4.1

Hot Swap

The GPZ-IPLE is not hot swappable and cannot be removed from the
GCD-CP10 without first powering down the chassis and removing the
GCD-CP10.
1.4.2

Connectors

The GPZ-IPLE has the following connectors:
CN1 - RJ-45 Gigabit Ethernet LAN Interface
CN3 - Connects to the GCD-CP10
1.4.3

Ethernet Status (IPLE)

Four LEDs (two red, one green and one yellow) on the GPZ-IPLE indicate
Ethernet connection status. The yellow LED is on when the Ethernet link is
up. The green LED flashes to indicate activity and the two red LEDs are
solid to indicate 10 Base-T/100 Base-TX or 1000 Base-T link speed.
1.4.4

Environmental Conditions

Temperature: +32 to 104 degrees Fahrenheit
Humidity: 10% ~ 90% (noncondensing)
Cable length of Ethernet cable: Up to 100m
1.4.5

Installation Procedure

Perform the following steps to install a GPZ-IPLE on the GCD-CP10:
WARNING
1.
Turn off the system power.
2.
Remove the GCD-CP10, and install the GPZ-IPLE on it.
3.
Insert the GCD-CP10 in slot 1 in the Controlling Chassis.
4.
Figure 5-3 GCD-CP10 Blade with Daughter Board
InstalledConnect the GPZ-IPLE to the CD-RTB or to an
external switching hub using an ethernet cable. Refer to the
UNIVERGE SV9100 Programming Manual for detailed
programming instructions.
1.4.6

Switch Settings

The daughter board has no switches to set.
Do not remove or install the GCD-CP10 with the power on.