Programming Procedure - NEC NEAX 2000 IPS Maintenance Manual

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

Programming Procedure

(1)
To set the fault information storage from the CAT/MAT by Command Operation
START
CM08
Enable the fault information storage fea-
ture.
Specify the processing at the time of fault
storage memory overflow.
CMEA
Assign which kind of fault information is
stored into the fault information memory,
and which kind of alarm is indicated.
NOTE:
CMEA programming can be set by the Fault Storage in MAT.
A
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
(1)
450
(2)
1
: To store
(1)
451
(2)
0
: No fault information is registered in
case of Fault Memory overflow
1
: Fault information is overwritten in
case of Fault Memory overflow
Y=2
(1)
See the following table.
(2)
See the following table.
– 12 –
FAULT MESSAGE
DATA
NWA-008847-001 Rev.3.0