NEC Univerge SV9100 Manual page 548

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
Level:
IN
Description
Use Program 51-01 : NetLink System Property Setting to define the parameters of
the NetLink feature.
NOTE
Input Data
Item
No.
01
02
03
SV9100 Networking Manual
Program 51 : NetLink Service
51-01 : NetLink System Property Setting
Each system must be set with its own information.
When the NetLink System ID is changed (Item 01), the system must be reset.
Item
NetLink System ID
This is the ID of each NetLink system. Setting
should insure that no overlap occurs between
nodes.
Primary Candidate Order
When the Primary system is turned off or
disconnect from network, this value is used to
select a new Primary system. Smaller number
is higher priority.
If this value is the same number, the System ID
(Program 51-01-01) is referred, and the
system which has the smaller number is
selected as Primary system.
Secondary System Flag
0: NetLink is dynamically established based on
Node List in Program 51-03-01.
Primary System is selected in the order which
the system wakes up.
1: The system connects with Top Priority
Primary System.
If Top Priority Primary System is not found, the
system searches Primary System as if this
setting is 0.
Input Data
0~50
(0 = No operation)
1~50
0
= Disable
1
= Enable
Default
0
30
0
10-61