NEC Univerge SV9100 Manual page 516

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
SV9100 Networking Manual
51-09-07 : NetLink TCP Port Settings – Database Replication Primary System
Detection Port
Define the port used for communication so that the Primary SV9100 may
synchronize the Secondary SV9100 with the program data (0~65535). If 0 is
entered, the port is selected dynamically.
51-10-01 : Remaining Virtual Slots
View the remaining number of slots which can be controlled by NetLink. The
NetLink feature can control up to 240 virtual slots maximum. (The physical slots
in the NetLink network are maintained as virtual slots by the SV9100.) This
option is not user-definable and is view-only.
51-11-01 - 51-11-06 : NetLink System Information
View the SV9100 information for communication servers connecting with the
Primary SV9100. These options are not user-definable and are view-only.
51-12-01 - 51-12-06 : Primary System Information
View the information for the Primary SV9100 in a NetLink network. These
options are not user-definable and are view-only.
51-13-01 : NetLink Option Settings – Automatic IP Address List Update
If this option is enabled (1), the Internet Protocol address list is updated to
include the IP address of a Secondary SV9100 upon connection.
51-13-02 : NetLink Option Settings – Time Zone Enhancing
When enabled (1), the time zone is applied to the following items: LCD Clock
Display, Caller ID History, VRS Time Announce, Time and Date Set by Service
Code, Alarm Clock, Hotel Mode Wake-Up Call (time announce included).
When disabled (0), the time zone is only applied to the LCD Clock Display and
Caller ID
History.
Program 51-02-02 must also be set for this option.
51-13-03 : NetLink Option Settings – MAC Address Authentication
When enabled (1), connection authentication of the SV9100 is done with the
MAC address set in Program 51-02-04. The system compares its own MAC
address and if the address does not match, the Primary System rejects the
connection.
51-14-01 : NetLink System Control – Delete System Information
Delete the SV9100 and slot information for a particular communications server
using the NetLink feature. To use this program, the communications server must
not be connected to the network.
51-15-01 : Easy Set Command
Automatically set the minimum settings for the NetLink feature. This program
sets up to four communication servers and applies the minimum settings
required to Programs 10-12-09, 51-01-01, 51-03-01, 51-04-01, and 51-05-02.
51-16-01 : NetLink System Data Replication Mode Setting – System Data
Replication Mode
Set the replication mode (0 = Disabled, 1 = Setting Time Mode, 2 = Interval
Mode). An entry of'1 replicates the data at the time set in 51-16-02. If this option
is set to 2, replication occurs at the interval set in 51-16-03.
51-16-02 : NetLink System Data Replication Mode Setting – System Data
Replication Time Setting
10-29