Issue 2.0
1.7
SV9100 Networking Manual
Open Number Programming Example
This sections provides the steps needed to program an open numbering plan.
Step 1: T1 Tie Lines
The following diagram provides an example of Program and item numbers that
should be assigned for T1 Tie lines. The example assumes that each UNIVERGE
SV9100 and Electra Elite IPK II system is defaulted with the GCD-CCTA blades
installed.
Abbreviations used in the diagram:
MB = Memory Block
CC = Clear Channel
UNIVERGE
SV9100
Tie Lines
25
TG 10
(101s)
101~130
PRG 10-03-05
Internal
PRG 10-03-03
CC = B8ZS
PRG 22-02-01
TRK 001~024 = Tie
PRG 14-05-01
TRK 001~024 = TG 10
PRG 14-02-13
TRK 001~024 = Yes
PRG 22-02-01
TRK 001~024 = Tie
PRG 34-01-01
TRK 001~024 = Wink
TRK = Trunk
TT = Trunk Type
UNIVERGE
SV9100
26
TG 10
TG 11
(201s)
101~130
PRG 10-03-05
External
Internal
PRG 10-03-03
CC = B8ZS
PRG 22-02-01
TRK 001~024 = Tie
TRK 025~048 = Tie
PRG 14-05-01
TRK 001~024 = TG 10
TRK 025~048 = TG 11
PRG 14-02-13
TRK 001~024 = Yes
TRK 025~048 = Yes
PRG 22-02-01
TRK 001~024 = Tie
TRK 024~048 = Tie
PRG 34-01-01
TRK 001~024 = Wink
TRK 025~048 = Wink
TG = Trunk Group
Electra Elite
IPK II
Tie Lines
27
TG 10
(301s)
101~130
PRG 10-03-05
External
PRG 10-03-03
CC = B8ZS
PRG 22-02-01
TRK 001~024 = Tie
PRG 14-05-01
TRK 001~024 = TG 10
PRG 14-02-13
TRK 001~024 = Yes
PRG 22-02-01
TRK 001~024 = Tie
PRG 34-01-01
TRK 001~024 = Wink
3-11