Card Interface Slot Assignment (Prg 10-03 Etu Setup); Digital Trunk Assignments - NEC Univerge SV9100 Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
NOTE
Card Type During 1st
Slot
Power On
1
GCD-CP10/GPZ-IPLE
2
GCD-8DLCA
3
GCD-8DLCA
4
None
5
GCD-4COTC
6
None
Program 10-03-01
Insert GPZ-IPLE on GCD-CP10 in Chassis 1, Slot 1.
Verify PRG 10-03-01 (ETU Setup).
Program 10-19-01
Assign DSP Resources 001~024 as CCIS (LK4).
Program 10-68
Assign the Trunk Type as CCIS with the Start Port
as 5 and Number of Port 24.
Program 14-05-01
Assign Trunks 5~28 in Trunk Group 10.
Program 22-02-01
Set Trunks 5~28 as Tie Line (LK6).
SV9100 Networking Manual
It is assumed that the systems were defaulted (first power on) with the
following blades installed as described below.:
4.2.1

Card Interface Slot Assignment (PRG 10-03 ETU Setup)

The following table provides information for assigning the blade interface
slots.
System A
Card Type
GCD-CP10/GPZ-IPLE
GCD-8DLCA
GCD-8DLCA
None
GCD-4COTC
None
4.2.2

Digital Trunk Assignments

Use the table below to make the appropriate assignments for digital trunks.
System A
Card Type and Ports
Ports
Card Type
Trunks 5 ~28
GCD-CP10/GPZ-IPLE
Station 1~8
GCD-8DLCA
Station 9~16
GCD-8DLCA
N/A
None
Trunks 1~4
GCD-4COTC
N/A
None
System B
Program 10-03-01
Insert GPZ-IPLE on GCD-CP10 in Chassis 1, Slot 1.
Verify PRG 10-03-01 (ETU Setup).
Program 10-19-01
Assign DSP Resources 001~024 as CCIS (LK4).
Program 10-68
Assign the Trunk Type as CCIS with the Start Port
as 5 and Number of Port 24.
Program 14-05-01
Assign Trunks 5~28 in Trunk Group 10.
Program 22-02-01
Set Trunks 5~28 as Tie Line (LK6).
System B
Ports
Trunks 5~28
Station 1~8
Station 9~16
N/A
Trunks 1~4
N/A
2-5

Advertisement