Level:
IN
Description
Use
Program 44-08 : Time Schedule for ARS/F-Route
feature. ARS/F-Route has 10 time patterns. These patterns are used in Program 44-09 and 44-10. The
daily pattern consists of 20 time settings.
Input Data
Default
All Schedule Patterns : 0:00 – 0:00, Mode 1
Example:
Pattern 1
0:00
8:00
Mode 3
Mode 1
Time Number 01 : 00:00 – 08:00 Mode 3
Time Number 02 : 08:00 – 18:00 Mode 1
Time Number 03 : 18:00 – 22:00 Mode 2
Time Number 04 : 22:00 – 00:00 Mode 3
Pattern 2
0:00
Mode 2
Time Number 01 : 0:00 – 0:00 Mode 2
13-148
Program 44 : ARS/F-Route Setup
44-08 : Time Schedule for ARS/F-Route
Schedule Pattern Number
Item
Time
Start Time
No.
Number
01
01~20
0000~2359
18:00
22:00
Mode 2
Mode 3
to define the daily pattern of the ARS/F-Route
End Time
0000~2359
0:00
0:00
01~10
Mode
1~8
Issue 2.0