Avaya Definity SI Maintenance Manual page 365

Table of Contents

Advertisement

display system-parameters maintenance
Alarm
Origination to
OSS Numbers
Cleared Alarm
Notification
Restart
Notification
Suspension
Threshold
Test Remote
Access Port
555-233-123
One of four options for alarm origination (neither):
If
both
, all Major and Minor alarms result in an automatic
call to both OSS telephone numbers. Both OSS telephone
numbers must be administered.
If
first-only
, all Major and Minor alarms result in an
automatic call to the first OSS number only. The switch
does not call the second OSS telephone number even if
the number is administered. The first OSS telephone
number must be administered
If
neither
, alarm origination does not take place.
Warning alarms are not reported to either numbers.
If
second-as-backup
result in an automatic call to the first OSS telephone
number. If calling the first OSS telephone number fails four
attempts, the switch starts to call the second OSS
telephone number as a backup until calling the first OSS
telephone number becomes successful. Both OSS
telephone numbers must be administered.
Before Release 5, the name of this field is
Origination Activated
deactivated, both Cleared Alarm Notification and Restart
Notification are disabled, even though they may still be
activated in the administration.
Enables the switch to originate a call to the OSS and send an
alarm resolution message whenever all previously-reported
Major and Minor alarms are resolved. Alarm Origination must
be activated in order for Cleared Alarm Notification to work. (n)
Enables the switch to originate a call to the OSS and report any
system restarts caused by problems with the switch.
The threshold for suspending Cleared Alarm Notification
(1-15). Some problems may cause alarms to be generated and
then resolved repeatedly. To detect these problems (by not
sending additional Cleared Alarm notifications to indicate a
problem- free system), the switch suspends Cleared Alarm
Notification when it has reported this administrable number of
Cleared Alarm notifications in a 24-hour period. A suspended
Cleared Alarm Notification is only enabled again with a
successfully completed "logoff" command, a system reset, or
when the threshold is changed. This field is irrelevant if Cleared
Alarm Notification or Alarm Origination is disabled.
Specifies whether testing of the remote access port on the
SYSAM circuit pack is enabled. This field should read
whenever there is an INADS line connected to the switch and
there is a maintenance contract in effect so that alarm
origination capability is maintained.
, all Major and Minor alarms
Alarm
. If Alarm Origination is
yes