File save command
Command area top
channel
+3
+2

Data Output (EtherNet/IP)

Either fixed point output or floating point output can be selected for data output.
Reference:
Fieldbus Data Output (p.586)

Timing Chart (EtherNet/IP)

I/O timing for each command is explained here.
The signal timing through EtherNet/IP is equivalent to parallel IO, and command execution and data
output are performed independently. This section explains the timing of command execution and data
output through the EXE signal.
When executing a command with the EXE signal
Important
Screen operation is not allowed when the EXE signal is turned ON. Make sure to turn the EXE signal OFF after
executing a command.
FZ4 User's Manual
Saves the Scene data
Saves the scene group data
Saves system data
Saves image data.
Saves all the image data in the image buffer (specified with [main unit
logging image])
Saves the last logging image
Saves System + Scene Group 0 data in a file
Executes a screen capture
Function
Control/Output through EtherNet/IP