Region size exceeds.
Please narrow region.
Logging error
The Logon to Network
Server screen is
displayed.
Although an error message such as the following, is not displayed, the ERROR signal and the ERR
indicator will turn ON.
8
The STEP signal was input when the READY
signal was turned OFF.
A non-existing parallel command was
entered.
The parallel scene group switch command
was executed when no USB memory was
installed.
(FZ4-L35
/6
574
Error Messages and Troubleshooting
There are restrictions as to what can be set up based on the camera and processing
items being used. Please adjust the region size so that the region is not too large.
Processing item
Shape search+
Barcodes+
2D Code+
Image logging failed due to insufficient memory at the save destination. The error
message disappears after 10 s. Please delete unneeded files in the save destination or
prepare a new USBDisk.
The connection was cut off based on the idling/session time set on the network logging
destination PC.
At the command prompt on the PC, enter
net config server /autodisconnect:-1,
and disable the automatic disconnection setting.
Cause
/7
only)
Region type
Measurement regions
Model region
Measurement regions
Measurement regions
Input the STEP signal after the READY signal turns ON.
Check to make sure that no chattering has occurred in the
STEP signal.
Noise is superimposed onto the STEP signal. Keep PLC and
FZ4 away from the noise source.
Please enter a correct parallel command.
Switch the scene group with the USB memory installed.
Region size (number of
pixels)
5003712
995328
1920000
1920000
Remedy