Clears measurement value by the parallel command
Output signal
Signal
RUN
Turns ON when the controller is set to the RUN window. Turns OFF in the ADJUST window.
Turns OFF when the command to clear the measurement value is being executed. Turns OFF as
READY
long as the BUSY signal is turned ON.
Turns ON when the measurement value is being cleared. The amount of time during which the
BUSY
BUSY signal is turned ON is approximately 1 ms.
Input signal
Signal
DI0 to 4
Turns the command OFF.
DI5
Turns the command OFF.
DI6
Turns the command ON.
This is the trigger signal to clear a measurement value.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms.
BUSY signal is ON during execution of commands. After checking that the BUSY signal has turned
DI7
ON, turn DI7 OFF, and then turn DI0 to 6 OFF. Note, however, that the amount of time during which
the BUSY signal is turned ON is approximately 1 ms. If it cannot be recognized whether the BUSY
signal is turned ON or not by an external device, control the timing so that the DI7 signal is turned
ON for approximately 5 ms.