Omron FZ4 Series User Manual page 423

Vision sensor
Table of Contents

Advertisement

Response (Controller to PLC)
Response
area
15-12
top channel
+2
0100
+3
0000
+4
0000
+5
0000
Data logging condition setting
Sets the data logging conditions for system data. Sets the "Data logging condition" on the Logging
Setting window .
Command (PLC to controller)
Command
Command
area
code
top channel
+2
4050
+3
0050
+4
+5
Response (Controller to PLC)
Response
area
15-12
top channel
+2
0100
+3
0000
+4
0000
+5
0000
Terminal offset setting
Sets the DI terminal offset data.
The terminal offset is the set value added to the command parameter specified with DI0-DI4.
FZ4 User's Manual
Bit
11-8
7-4
0000
0100
0000
0101
0000
0000
0000
0000
Bit
15-12
11-8
0100
0000
0000
0000
0000
0000
0000
0000
Bit
11-8
7-4
0000
0101
0000
0101
0000
0000
0000
0000
Communicating through Serial Communication (PLC Link)
3-0
0000
Command code
0000
Store response target command codes.
0000
Response code
Command execution result
OK: 0 (0000 0000)
0000
NG: -1 (FFFF FFFF)
7-4
3-0
0101
0000
0101
0000
0000
0000
0000
0000
3-0
0000
Command code
0000
Store response target command codes.
0000
Response code
Command execution result
OK: 0 (0000 0000)
0000
NG: -1 (FFFF FFFF)
Description
Description
Sets command codes.
Specifies the data logging
conditions.
0: None
1: Only NG
2: All
Description