Note
Some of these short cuts have functions, such as scene switching, which affect measurement.A
password protection function can be added in order to restrict use.
Reference:
Setting User Group Operation Restrictions (p.141)

Setting the Encoder Trigger [Encoder Trigger Setting]

1.
On the Main screen, tap the [System] menu - [Controller] - [Encoder trigger setting].
2.
Set the target encoder.
Set value
Setting item
[Factory default]
Use Encoder
Checked
trigger
[Unchecked]
Resolution
[1] to 65535
Count
Checked
rotations
[Unchecked]
with pulse Z
FZ4 User's Manual
Description
Sets whether the encoder trigger will be used.
The maximum input frequency of the encoder trigger is 20 kHz.
Sets how many pulses equal one rotation. Please set
according to the resolution of the encoder.
When on, judges whether it made a full rotation with pulse Z.
When off, judges whether it made a full rotation based on
whether phase A pulse input reaches phase A resolution.