Omron FZ4 Series User Manual page 394

Vision sensor
Table of Contents

Advertisement

+4
+5
Important
For non-remote operation, only 0: Local can be specified. For remote operation, only 1: Remote can be
specified.
If this command is executed with any combination other than the above, it is not supported in Ver. 4.20.
Note that unexpected operations could occur.
Response (Controller to PLC)
Response
area
top channel
+2
7
+3
+4
+5
+6
+7
Getting display image unit number
Gets the number of the unit currently displayed in the specified image display window.
Command (PLC to controller)
Command
area
top channel
+2
+3
+4
+5
392
Communicating through Serial Communication (PLC Link)
0000
0000
Bit
15-12
11-8
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Command
15-12
code
5010
0101
0020
0000
0000
0000
0000
0000
0000
0000
7-4
3-0
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0010
0000
0000
0000
0000
0000
Specifies the item to
acquire.
0: Local
0000
1: Remote
Description
Command code
Store response target command codes.
Response code
Command execution result
OK: 0 (0000 0000)
NG: -1 (FFFF FFFF)
Response data
Layout No.
0: Adjust window, 1: Run window
Description
3-0
0000
Sets command codes.
0000
0000
Specifies the display
image window number.
1-screen display: 1
2-screen display, 1, 2
0000
4-screen display: 1 to 4
Thumbnail display: 0 to 4
FZ4 User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz4 series

Table of Contents